60
DHOLLANDIA
The electrical platform mounted options (flashing lights, foot controls, etc.) function properly.
4 - Inspection of the hydraulic part
There are no visible oil leaks after the load test tests in operation and at rest.
The visible oil level corresponds with the oil level instructions of this manual.
The hydraulic circuits have been purged to remove any remaining air.
During the various movements of the lift, the flexible oil pipes stay clear from the vehicle chassis & body. They cannot be
damaged by rubbing, squeezing, etc.
None of the thermoplastic pipes has been damaged or marked during welding.
The cover of the pump unit is mounted and securely latched.
5 - Inspection of the platform
The centre point of maximum load is correctly marked and corresponds with the data mentioned on the identification sticker
supplied with the tail lift.
The safe working zone for the operator is clearly and permanently marked on the platform (if applicable). The provided foot
protection conforms with the fitting instructions.
The platform is made sufficiently visible for the surrounding traffic (platform lights, flags, reflective tape, traffic cones,…)
At vehicle floor level, the platform aligns flush with the extension plate.
A hand grip for the operator to hold when lifting / lowering with the platform, is mounted on the rear frame of the vehicle
body.
7- General operation, practical tests
Unfolding and folding test:
▢
The platform opener is mounted in adequate position. When LOWERED at the ground, the platform stands just inside
from vertical position.
▢
The platform unfolds and folds without touching the vehicle chassis.
General operation with an empty platform: execute all movements several times with ALL available control units. The tail
lift should work smoothly and quietly, and almost silently, through its full range of motion.
▢
Gravity down lifts: during LIFT, only the sound of the running DC motor in the pump unit should be audible.
▢
Power down lifts: the sound of the running DC motor in the pump unit will be audible during LIFT and LOWER
movements.
▢
Any other (creaking, grinding or squeaking) noise should be carefully investigated and solved.
Dynamic test at 100% of maximum rated lift capacity:
▢
Verify if the lift has sufficient lift capacity.
▢
Verify the general performance & stability.
Содержание DH-RP.10
Страница 12: ...11 DHOLLANDIA Figure 6 2 MFT MTG...
Страница 34: ...33 DHOLLANDIA Figure 11 5 Figure 11 4...
Страница 50: ...49 DHOLLANDIA...
Страница 53: ...52 DHOLLANDIA EF0583 RM EN EF0565 EN EF0618 EN EF0570 CAP serial nr EF0564 EN EF0563 EN EF0562 EN xxxx...
Страница 65: ...64 DHOLLANDIA Figure 19 4 Figure 19 5...
Страница 75: ...74 DHOLLANDIA...
Страница 76: ...75 DHOLLANDIA...