EN
A29
DHOLLANDIA
N°
Description
...
...
12
13
Main battery fuse on the (+) battery cable
15A fuse on the wires inside the power pack
Both fuses are used to protect the electrical system
against short-circuit and amperage peaks.
14
Hydraulic flow control : the main valve in the hydraulic
power pack is equipped with a braking valve, retaining
the descend speed within legal boundaries: max.
15cm / sec for vertical movements.
15
Emergency hand pump: allows to LIFT the platform in
case of electrical failure (battery deficiency, damaged
fuse, damaged electrical controls...)
16
Emergency exit button: allows to LOWER the platform
in case of electrical failure (battery deficiency,
damaged fuse, damaged electrical controls...)
17
EMR = Emergency Motor Release
Enables the operator to SLIDE the platform IN / OUT
manually in case of electrical failure (battery
deficiency, damaged fuse, damaged electrical
controls...), after releasing the automatic cassette
lock.
18
Load detection / pressure relief valve : permits the
manufacturer and the installer to limit the final
performance of the lift to its nominal capacity, and
protects it against overload during the LIFT cycle.
...
...
8
Fig. 4.6
17
16
13
15
18