background image

Configuration

devolo G3-PLC Modem 500k

39

remote G3-PLC modems that are intended to use this bus are configured as clients on
the port for the serial bus.

���

Combination of 

���

 and 

���

Scenario 

���

 allows a master to operate independently with multiple, remote serial in-

terfaces. Nevertheless, a special program would have to be developed to combine these
remote interfaces to create a virtual serial bus. Scenario 

���

, in turn, offers a virtual se-

rial bus only if the master also has a serial interface.

It is also possible, however, to activate a virtual serial bus directly over IP. In this case,
the G3-PLC modems are configured as described in Chapter 

���

. There is no master

connected to the RS485 port of the local G3-PLC modem. There is either nothing or
there are additional slaves of the virtual serial bus. The master connected over a LAN
communicates with the local G3-PLC modem (as is the case with the remote G3-PLC
modems under 

���

). This means that it establishes a TCP connection to the server's port

or sends UDP packets there. Then the data are sent to the local serial port and to all

Fig. 9

Содержание G3-PLC Modem 500k

Страница 1: ...devolo G3 PLC Modem 500k...

Страница 2: ...G3 PLC Modem 500k...

Страница 3: ...ts is subject to written authorization from devolo We reserve the right to make any alterations that arise as the result of technical development Trademarks G3 PLC TM is a registered trademark of G3 P...

Страница 4: ...coordinator installation 13 3 3 2 PAN client installation 14 3 3 3 Testing the network 15 4 Configuration 17 4 1 Configuration interface 17 4 1 1 Overview page 18 4 2 Network configuration 18 4 2 1 IP...

Страница 5: ...his section contains a brief description of the icons used in this manual Very important note Failure to observe this note may result in damage Important note that should be observed The device may on...

Страница 6: ...evolo on the Internet For detailed information on our products visit www devolo com smart The download area provides you not only with product descriptions and documenta tion but also updates for devo...

Страница 7: ...ral conductor Authentication via EAP PSK Encryption using AES 128 Serial RS232 or RS485 over G3 PLC functionality 2 1 1What role does the modem play There are two different roles within a G3 PLC netwo...

Страница 8: ...alling some PAN clients then the PAN coordinator For setting up a G3 PLC network start by putting some PAN clients into operation and then define a suitable location for the PAN coordinator Communicat...

Страница 9: ...low Ethernet connection You can connect the G3 PLC Modem 500k to a smart meter gateway or another Ether net device using an Ethernet cable RS232 RS485 port You can find a list of the protocols and app...

Страница 10: ...f the de vice is summarised in the following table Reset button You can use a pointed object to press the reset button It has two different func tions The device restarts if you press the Reset button...

Страница 11: ...nected to the distribution station on a shared supply line and are connected together to form one communication cluster G3 PLC network Communication is transmitted using PLC from the households to the...

Страница 12: ...working with live voltage This is only permitted for skilled persons with the corresponding qualifications such as the German AuS Pass Additional restrictions on installation authorisation may apply...

Страница 13: ...the PAN coordinator as close to the centre of the network as possible so that as many PAN clients as possible can connect to it directly G3 PLC technology does feature a repeating function but you sh...

Страница 14: ...er to determine the best possible location for the PAN coordinator later on be aware that no communication is possible within the G3 PLC network until the PAN coordinator is installed and online Once...

Страница 15: ...s before a new attempt is initiated to pair with the PAN coordinator This time interval between attempts is random but tends to increase If a PAN coordinator cannot be accessed for a long period of ti...

Страница 16: ...Modem 500k 16 work we recommend using an upstream router This reduces the broadcast domain see also Chapter 4 3 1 Mode PAN coordinator Metering data Local data for other applications Fig 3 G3 PLC net...

Страница 17: ...PLC Modem 500k in the factory defaults The configuration has no effect on piping data via the modem The full functionality for piping IPv4 and IPv6 packets is specified here Note the different MAC ad...

Страница 18: ...s you update the firmware of your device Define the access restrictions for your device or the G3 PLC network in the Secu rity area Configure piping of the serial interface over the G3 PLC network in...

Страница 19: ...ynchronise the date and time Select your Time zone and the Time server A DNS server must be entered when entering a time server name manually or via DHCP No DNS server needs to be present in the netwo...

Страница 20: ...s setting so that different prioritisations remain possible depending on the service Packets destined for devices which are not on the network are discarded If this option is enabled undeliverable Uni...

Страница 21: ...used to reduce the load on the G3 PLC network Broadcast packets are data packets without a unique destination address Broadcast packets that go to a G3 PLC Modem 500k over the Ethernet interface are s...

Страница 22: ...t premature retransmission of supposedly lost data packets in order to optimise the utilisation of the G3 PLC network 4 3 2Mode PAN client If the G3 PLC Modem 500k is to be configured as a PAN client...

Страница 23: ...ork without transmission Receiver devices are not detected as being available in the network if the number of consecutive lost packets to that node meets or exceeds the value configured under Maximum...

Страница 24: ...ta rate of 24 kbps has been determined for broadcast transmissions Communication between PAN clients If you enable the Communication between PAN clients option you are allowing data communication betw...

Страница 25: ...ect PAN automatically option is enabled the PAN clients change the G3 PLC network For this reason you should regulate the IP address assignment using DHCP no static IP addresses Select PAN automatical...

Страница 26: ...en two accessible G3 PLC networks If the PAN client can access more than one PAN coordinator the LQI Line Quality Indicator a metric for connection quality decides to which G3 PLC network the PAN clie...

Страница 27: ...rdinator connection If you enable this option repeating connections are selected only if a direct connection cannot be made from the PAN client to the PAN coordinator regardless of the connec tion qua...

Страница 28: ...TxQueueLen field number of data packets This setting is important when using TCP protocols because a certain predetermined number of data packets window size transmission or reception window size can...

Страница 29: ...of the G3 PLC Modem 500k you can find an assortment of device information in the drop down list OnlineStatus As soon as a PAN client has paired with a PAN coordinator it receives the online sta tus Th...

Страница 30: ...e starting the modem after a software update or a power failure are recorded in the Re start or Process start counter 4 4 2Topology You can view the connected modems in the topology overview Each devi...

Страница 31: ...yed between the repeater stages just like with the path information You can find the algorithm for calculating the LQI in ITU T G 9903 Annex B Routing cost Example The logical topology is specified in...

Страница 32: ...www devolo com smart and download the appropriate file for the G3 PLC Modem 500k onto your computer Then in the configuration dialogue go to the Update firmware area Click Select file and select the d...

Страница 33: ...ecify a login password for access to the configuration interface The built in configuration interface of the G3 PLC Modem 500k is assigned the factory default password admin as a means of providing so...

Страница 34: ...ically The index is generated by the PAN coordinator automatically when pairing a new device The PLC MAC address is permanently associated with the device You can refresh the list and remove PAN clien...

Страница 35: ...6Restore the network access whitelist To restore a saved network access whitelist select the network access whitelist file with Select file and then confirm your selection with Restore file This funct...

Страница 36: ...e IP is used for the serial pipe If the G3 PLC Modem 500k assumes the client role the IP address of the server mo dem must be specified The port number of both devices server and client must be identi...

Страница 37: ...ver IP Then this device becomes the IP server and the other becomes the IP client device The port must be identical The buffer size and timeout values have to be selected based on the requirements of...

Страница 38: ...wo remote G3 PLC modems This allows the mas ter to communicate with all connected serial devices The two G3 PLC modems can also be configured as clients which requires that they have the IP address of...

Страница 39: ...only if the master also has a serial interface It is also possible however to activate a virtual serial bus directly over IP In this case the G3 PLC modems are configured as described in Chapter There...

Страница 40: ...te that the preset configuration is to be used again automatically after a set period In this case you can select a time from 10 10 000 ms The timer restarts with every character sent over IP or the s...

Страница 41: ...maximum 19 200 bps or a unidirectional transmission with a maximum 38 400 bps and a latency of less than 1 second are possible Higher data rates require corresponding breaks in the data stream For a r...

Страница 42: ...or lights LEDs 10 Installation alignment 13 IP address 17 18 IPv4 17 IPv6 17 L License information 32 Line connections 10 LQI 31 M MAC address 14 17 N Network access whitelist 34 Network plan 15 Neutr...

Отзывы: