Configuration
devolo G3-PLC Modem 500k
19
The IPv4 address is only necessary for configuring and managing the device.
If you assign a static IP address, make the corresponding entries under
IP ad-
dress
,
Netmask
,
Default gateway
and
Name server
and click
Save
to confirm your
entries.
4.2.2Date and time
A time server is a server in the network whose task consists of providing the exact time.
Enable the option
Retrieve date and time automatically
, so that the G3-
PLC Modem 500k can automatically synchronise the date and time. Select your
Time
zone
and the
Time server
.
A DNS server must be entered when entering a time server name (manually
or via DHCP).
No DNS server needs to be present in the network if an IPv4
address is entered.
If you have enabled the option
Adjust to daylight savings time automatically
, the
G3-PLC Modem 500k automatically adjust to daylight savings time. Confirm your en-
tries with
Save
.
4.3 Modem configuration
The
Modem configuration
area lets you specify the mode of the device and the set-
tings for data communication.
The device has two different modes:
PAN coordinator
and
PAN client
. Depending
on the selection, the corresponding configuration options are displayed.