4.7 Serial interface
Here you can configure the serial interface and piping of required data to a remote G3-
PLC modem or another TCP communication partner over a TCP connection.
The G3-PLC Modem 500k parameters must match the settings of the connected de-
vice. You can only ever establish a point-to-point connection (TCP) between the G3-
PLC modem and a TCP communication partner. This may be a G3-PLC modem or an-
other type of remote device.
Activate the
Enable pipe
option to enable piping of the data being transmitted and
specify the
parameters of the serial interface
.
IP is used for the serial pipe
If the G3-PLC Modem 500k assumes the "client" role, the IP address of the server mo-
dem must be specified. The port number of both devices (server and client) must be
identical.
Communicate with multiple devices via IP like a serial bus
Enter the number of the port to which the devices are to connect.
Select whether or not you would like
processing of in-band configuration parame-
ters
.
These parameters control the latency:
The data received via the serial interface are sent using IP packets. The maximum
packet size can be configured. As soon as the configured data quantity has been cached
in the device, a data packet of that size is sent. If packets of the specified size cannot
be filled, the system waits the specified
timeout
and then the data are sent using a
smaller IP packet.