21
DST
Series
3.0
Installation
•
Unvented Operation
•
Installation of Exhaust Hood
12 in. Min.
12 in. Min.
Figure 3.8
•
Minimum End Clearances
Unvented
heaters
All heaters
NOTE:
Gravity or mechanical means may be used to accomplish the air displacement.
Local codes may require that the mechanical exhaust system be interlocked with the
electrical supply line to the heaters, enabling both to function simultaneously.
• The minimum clearance between the air intake and the exhaust terminal is 4 ft.
• Exhaust openings for removing the flue products must be located above the level of the
heater(s).
NOTE:
Applies to all models. DST-80N models are to be un-vented.
1
Remove any existing exhaust venting from radiant tube.
2
Using a 1/4” nut driver, attach exhaust hood to heater end using screws (4).
Figure 3.9
•
Exhaust Hood Installation
Installation of Exhaust Hood When not Venting Through Roof or Sidewall