11
DST
Series
12.75”
2”
3.0
Installation
•
Recommended Mounting Heights
* Factory recommended mounting heights are listed as a guideline. If infrared heaters are mounted too low
or too high, they may result in discomfort or lack of heat. Detroit Radiant Products Company generally
recommends observing the recommended mounting heights to optimize comfort conditions. However,
certain applications such as spot heating, freeze protection, outdoor patio heating or very high ceilings
may result in the heaters being mounted outside of the factory recommended mounting heights.
Chart 3.1
•
Recommended Mounting Heights and Coverages for DST Series Heaters
NOTE:
This chart is provided as a guideline. Actual conditions may dictate variation from this data.
Figure 3.2
•
Mounting Height Dimensions
(see Chart 3.1 for dimensions)
Max.
Input
(BTU/h)
Typical or
Recommended
Mounting Height*
Coverage Area
Straight
Config. (LxW)
Distance
Between
Heaters (ft.)
Dim. A
Distance
Between
Heater Rows
Dim. B
Max. Distance
Between
Heaters and
Wall - Dim. C
60,000
8’ - 14’
20’ x 12’
10’ - 20’
20’ - 40’
16’
80,000
9’ - 15’
20’ x 12’
10’ - 20’
20’ - 40’
16’
NOTE:
Dimensions A, B & C are based upon heaters hung at the factory recommended mounting height.
Dim. C
Dim. A
Dim. B
Dim. C
Dim. A
Figure 3.1
•
Heater Dimensions
10.5”
17.25”
SIDE VIEW
END VIEW
3”
114”
119”
24.5”
63”
24.5”
Содержание DST-60N
Страница 51: ...51 DST Series 5 0 Maintenance Notes Notes...