background image

Detection Systems 

 

Abacus User Guide 

 

 

Chapter 4.14 

 

Codes 
 

There is a variation of user codes available each with a greater or lesser access and control over the 
installation. (See System Features for number of codes and digits available). 
 

Master Code 

 
The master code can operate and program all the user function available on the Abacus panel as listed 
below: 
 
 

Program and remove all user codes. 

 

Program the date and time, and chime function. 

 

Allowing the engineer or remote modem access to engineer functions. 

 

Read the log events. 
Test the System (Except for active zones). 

 

Can Set, Part Set and Unset all areas. 

 

Can isolate or omit areas and certain zones. 

 

Main Code 

 
The main user code has the same function as the master code, except that it is unable to program or 
remove codes, or change the engineer lock/ unlock function. 
 

On version 5000 software or later, the master code user can limit the area access available to the main 
user code holder. 
 

On Off Code  

 

The On Off code, introduced at version 7000 softwarw, Sets, Part-Sets and Unsets all areas.  It cannot 
omit any zones or change any program functions. 

 

Area 1, 2 or 3 Codes

 

 
An area code holder is only able to Set, Partset or Unset that specific area.  (i.e.  Area 2 code sets/unsets 
Area 2) The area code cannot omit zones or control other function on the system.  

 
Cleaner Code

 

 

See system features for availability on your installation. 

 

A code programmed as cleaner is used to unset specific zones in several areas (I.e. a Cleaner or 
Security Guard is required to unset all the corridors but not the offices). When entered in the unset 
mode only displays ‘Cleaner on Site’ but when set, unsets and Sets all zones programmed as cleaner.  
Other codes can override this function (i.e. An area code when used to set an area is requested 
‘Cleaner on site ok?’ – if replied NO then panel sets all zones in that area, if replied YES then panel set 
those zones not programmed as cleaner in that area). 

 

Duress Code

 

 
This is a special code that will set, part set or unset all areas. 

BUT first it signals a duress signal to 

central station 

(a silent personal attack to alert the alarm monitoring service that the system is being 

Set/Unset under duress).  

 
On version 5000 software, the master code user can limit the area access available to the Duress user 
code.  On version 7000 software duress code is again for all areas. 

 

Содержание abacus 15R

Страница 1: ...Detection System s Part Number D247 152 Issue 2 Oct 2001 ABACUS LCD User Guide A member of the Bosch Group...

Страница 2: ...ccur should be taken up with the installation company Italics are used in the text to denote indicate special differences between the Abacus panels and in the index to indicate main drawings charts or...

Страница 3: ...Time Bell Delay Time Sounder Tones Keypad Tone Confirmation Tone Chime Tone Exit Tone Part Setting Tone Entry Tone Alarm Tamper or Bad Set Tone Page 1 8 Fire Alarm System Detectors Door Contacts Move...

Страница 4: ...ting Routine Reset the System User Reset Engineer Reset Remote Reset Page 2 12 Code Reset Page 2 13 Setting Options Flow Chart Unsetting Options Flow Chart Chapter 3 Programming Page 3 1 General Key S...

Страница 5: ...r alarm system You are able to instruct the system on your requirements by pushing one or more of the twelve control keys 1 to 9 0 ESC NO or YES PART keys The control panel will inform you of its stat...

Страница 6: ...se 10 Upper lower case Number of codes 15 15 15 99 Remote Keypads 7 LCD 7 LCD 6 LCD 7 LCD On board display type None None LCD None Zones Circuits 6 Exp to 14 zones 28 circuits 6 Exp to 14 zones 28 cir...

Страница 7: ...to any code by the Engineer Main or Duress codes can now be programmed for specific areas On timed Exit or Exit terminate not contact set the entry time is doubled when entry is by a FX detector on a...

Страница 8: ...ed with Engineer read log displayed Unused zones may be disabled by programming Zone six may be used for silent signalling on point ID or SIA Abacus 8 80 Improved Factory Default Settings On alarm dis...

Страница 9: ...n the system will only part set This means that to do a full set you must leave the protected location Exit Zones circuits located on the exit entry route are described as exit route detectors these d...

Страница 10: ...us until setting signal is received is set to give you time to leave your premises On entering the users code factory Default is 1234 the exit timer is started and a warning sound is given to tell you...

Страница 11: ...tone at normal as exit tone setting or low volume i e panel silent Part Set confirmation version 7000 software Chime Tone A tone of pulses is produced for 2 seconds when an Exit Terminator doorbell is...

Страница 12: ...her the panel is set or unset will signal a personnel attack alarm PA to the central station if a communicator is fitted The PA alarm may be silent alarm or a full alarm bells and sounders as programm...

Страница 13: ...reas such as in a factory to enable the office workshops and stores to be controlled separately Area 1 2 and 3 The Abacus panels can operate with up to 3 areas plus a common and cleaner area See Syste...

Страница 14: ...change any program functions Area 1 2 or 3 Codes An area code holder is only able to Set Partset or Unset that specific area i e Area 2 code sets unsets Area 2 The area code cannot omit zones or cont...

Страница 15: ...Engineer Lockout in chapter 3 Note Although the engineer code can set and unset an installation it cannot unset an installation that has been set by a user code If an installation has been set by an...

Страница 16: ...e Continuity Insulation Volt Drop Notes 01 02 03 04 05 06 07 08 09 11 10 12 11 13 12 14 13 15 14 16 15 17 18 Continuity Insulation Notes Keypad Bus Bell cable Speaker Voltage Current Notes Mains Batte...

Страница 17: ...r Address S Eng Tel No The above table has been given to enable a record to be made of your installation by the engineer and to be of use when servicing is carried out Your installation company may us...

Страница 18: ...this numbers have been moved to the O ESC key See second Chart below Abacus 8 15P uses old chart no library Key Stroke Character Chart a 1 b 11 c 111 A 1111 B 11111 C 111111 1 1111111 d 2 e 22 f 222...

Страница 19: ...ter the User master code 1234 At this display press the NO key XXXXXX Code holders name if programmed Press the NO key On Version 7000 software this display appears to allow you to return to the day m...

Страница 20: ...key to accept Repeat for Duress Software version 5000 only on pressing the YES PART key the display changes to Press the 4 key to return to the day mode and check that the new number s works and any...

Страница 21: ...eat to delete further codes as required Abacus 8 80 to index in 10s i e key in 3 to jump to code 30 On completion press 0 ESC once Twice for mode 2 operation Version 5000 software Press the 4 key to r...

Страница 22: ...day mode if you have made a mistake press YES PART key to continue At this display press the NO key At this display press the 1 key to enter the programming mode At this display press the 3 key to ent...

Страница 23: ...d the installation engineer requires you to place the installation at the Engineer mode as shown below From the day mode enter either a Master or Main code Main code cannot lock unlock the engineer ac...

Страница 24: ...0 ESC YES PART 0 ESC Enter User Code Unset Day Mode Set System Omit Zones See Page 3 2 Code Programming Page 3 3 To Delete a Code See Page 3 4 To Program Chime See Page 3 6 To Lock Unlock Engineer Pro...

Страница 25: ...splayed Internal Sounder Checks Each day as you set and unset your Abacus alarm panel check that your exit entry tones can be heard Also regularly check that the chime tone is generated from the exit...

Страница 26: ...e zone active test was also reset each time the system was set This reset was discontinued to enable the user to check for zone activation over a period of time From this menu press the 2 key for test...

Страница 27: ...ed by the 4 key to return to the day mode Alarm Fault Display Date Time Zone state or condition If the descriptor message has been programmed when reading the log press the 1 key for the additional in...

Страница 28: ...ith print out facility will print out the log Version 5000 or later software on pressing the 3 key before print out commences you are given a date range choice At this menu by pressing the YES PART ke...

Страница 29: ...ystem Noted from event above Ameet although either a main or master code user only unset area 1 Using keypad 4 at 2 20 PM and 15 seconds on the 15th of February Gary set the installation at 10 30 AM a...

Страница 30: ...ne 3A the lounge detector was omitted or on test When the panel was set all zones programmed as part were omitted i e all of the bedrooms On attempting to set the panel zone 3 the kitchen PIR was in a...

Страница 31: ...TRBL FTC 1502 081010 TRBL Line Cut 1502 081010 TRBL No Tones 1502 081010 Ack CS 1502 120004 Watch Dog 1502 081010 TAMP Front Door 01 FX 1502 081010 TAMP Bell 1502 081010 TAMP System 1502 081010 TAMP...

Страница 32: ...to carry out a reset It also carries out a reset at power up A tamper was detected on the front door connected to zone 1 i e the wires to the front door detector has been cut A tamper has been detecte...

Страница 33: ...of the 15th of February and or a time of 8 10 AM A smoke detector on the landing connected to zone 6 cct B has been activated and signalled fire The panel was reset after generating a Fire Alarm A be...

Страница 34: ...system you are also reminded that a service is required If you ignore this request for 14 days Version 5000 software or later 28 days the panel will lock out and you will not be able to set the system...

Страница 35: ...Detection Systems Abacus User Guide Chapter 4 35...

Отзывы: