Detection Systems
Abacus User Guide
Chapter 4.26
At this display, press the
NO
key.
At this display, press the
2
key to enter the test mode.
At this display, press the
1
key to test zones.
This display will change and indicate the zone as
they are activated. At the same time, the sounder
is turned On (i.e. zone 2A a Hallway PIR). If an
Exit Terminate button is fitted, and pushed, it
will be displayed as Exit Terminate.
Do not activate PA, Fire, or 24 hour Detectors, leave testing of these types of detectors to the alarm
engineer.
If required press the
YES/PART
to toggle the SW12 V to unlatch detectors if required.
Test all detectors in turn and check that they respond correctly. Press the
0/ESC
key to return to:
At this display press
0/ESC
key
and then the
4
key to return to the Day
mode, or carry out further tests as follows.
Zone Active Test
To reset the zone active test, first enter then escape from the zone test above.
On early versions of
software, the zone active test was also reset each time the system was set. This reset was discontinued
to enable the user to check for zone activation over a period of time.
From this menu, press the
2
key for test.
At this display, press the
4
key for active test.
At this display, once a zone has been activated the corresponding number is
deleted from the display.
On the larger Abacus systems, the display is
changed to indicate the group of zones, in which case press the
YES/PART
key, to step on to the next group of zones as required.
Caution.
Do not activate PA, Fire, or 24 hour Detectors, leave testing of these types of detectors to
the alarm engineer.
Walk round your installation and activate all detector zones in turn, then ensure that the appropriate
number has been removed from the display
.
When completed press the
0/ESC
key.
At this display, press the
1
key, followed by the
0/ESC
to reset the active
display and return to this display.
Omit Zones ?
1=Prog 2=Test
3=Log
4=Day(Quit)
1=Zone 2=Bell
4=Active
Test
ok!
Test
02A
Hallway PIR
1=Zone 2=Bell
4=Active
1
=Prog 2=Test
3=Log
4=Day(Quit)
1=Zone 2=Bell
4=Active
A <INACTIVE> B
123456 123456
1=Zone 2=Bell
4=Active