Notes.
Should a incorrect value be inserted the panel will appear to lock up, enter the correct value
and the panel will start functioning again (i.e. if 15 is keyed in for the month, then key in say
01 YES/PART for January).
The clock is stopped during time programming and restarts on completion (i.e. restart
as soon as display shows 1 = Prog etc. menus above).
Lock and Unlock Engineer Programming or Engineer Access via Modem
From the day mode, the engineer can with his/her code operate the system and change all the
programming functions on your installation, providing that you have left the user programming as
engineer Unlocked. If you program as engineer Locked, the engineer is limited to operating and testing
only, and requires the user’s master or main code to change any engineer programming functions. This
enables you to be aware of any changes to your installation performance.
If your installation as been set for Association of British Insurer (ABI) mode for modem
communication (Upload/Download) the installation engineer requires you to place the installation at
the Engineer mode as shown below.
From the day mode, enter either a Master or Main code. (Main code cannot
lock/ unlock the engineer access).
At this display, press the
NO
key. . (XXXXXX = Code holders name if
programmed).
On Version 7000 software, this display appears to allow you to return to the
day mode if you have made a mistake, press
YES/PART
key to continue
.
At this display, press the
NO
key.
At this display, press the
1
key to enter the programming mode.
At this display, press the
4
key to enter the Engineer-programming mode.
Leave at this menu for engineer access via modem
. (
Strobe will flash to
warn you that the panel is left at access for modem version 5000 software
).
To program the Lock/Unlock function, press the
NO
key.
At this display, press the
NO
key to toggle between LOCKED and
UNLOCKED, then press the
YES/PART
key to accept. (This function is
only available to the Master code).
At this display, press the
0/ESC
key, then the
4
key to return to the day
mode.
0712 03:46P
System Off
Hello XXXXXX
Set System?
Omit Zones ?
1=Prog 2=Test
3=Log
4=Day(Quit)
1=Code 2=Chime
3=Time
4=Engnr
Engineer Code
Engineer Access
is UNLOCKED
ok?
1=Code 2=Chime
3=Time
4=Engnr
YES: to Continue
No: to Quit