90
11.2 Commands
11.2.1 Display values
Displays the values of the previous screwing level at the touch display. The command can
used as often as you like.
11.2.2 Save values
Saves the values of the previous screwing level into the end value data set. The command
can be used as often as you like (also see
).
IMPORTANT
As a maximum the last three results are saved.
11.2.3 Statistic
Affects the calculation of the statistic of the previous screw level (also see
).
IMPORTANT
The statistic can only be calculated for a screwing level per program. If
the 'statistic' command is entered more than once into the program then
only the statistic for the last screwing level is calculated, for which the
'statistic' command has been indicated.
11.2.4 Print
Causes the output of the result of the preceding step on the serial printer interface.
IMPORTANT
One precondition is that a printer is connected to the multifunctional
printer interface and the printer is configured as a device on the serial
interface (see
).
Data is printed after OK or NOT OK screw assembly according to the
system settings.
11.2.5 Waiting time
Inserts a waiting time into the program.
Parameter:
• Waiting time
11.2.6 Hold position
Hold the screwdriver tension position.
Parameter:
• Holding time