![Deprag AST11-1 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/deprag/ast11-1/ast11-1_operating-instruction-booklet_2485169103.webp)
103
14.1.4 Communication
Number
Meaning
Trouble shooting
301 No
connection
302 General
error
303 Checksum
error
304
Module not found
305 Unknown
command
306 Timeout
307
Access to write-protected area
308
Value outside of limits!
Switch the AST11 off and then restart again.
Table 30:
System error – Communication
14.2 Error in the screwing sequence
Number
Displayed text
Meaning
Troubleshooting
0 OK
No error, the screwing applica-
tion was ended properly
-
1 TIME
LIMIT
The set monitoring time of the
screwing level has been ex-
ceeded
2 ANGLE
LOW
The indicated minimum angle
of the screwing level was not
reached
3 ANGLE
HIGH
The set maximum angle of the
screwing level has not been
reached
4 TORQUE
LOW
The indicated minimum torque
of the screwing level was not
reached
5 TORQUE
HIGH
The set maximum torque of the
screwing level has been ex-
ceeded
Check the screw process and
adapt the program if required.
6 PU:
PROG?
An invalid program was trans-
mitted to the Power unit
Transfer the program over
again.
7 DRIVER
IO
The program contains too
many E/A commands
Check the screwdriver pro-
gram.
8 START
?
There are too many start sig-
nals.
Check the applied start sig-
nals. Apply only one start sig-
nal.
9 INVALID
PROG
Program is not valid (does not
exist, or was created for an-
other screwdriver)
Check the program and adapt
if required or select a different
program.
10 INTERRUPT
The start signal has been reset
prior to the normal end of the
screwing application.
The start signal must be pre-
sent until the end of the
screwdriver operation.
Содержание AST11-1