94
12.3 Statistic
If the command "statistic" is used in the screwing program then in the sequence controller
AST11 a statistic is kept about the last 100 values for the respective program.
The following values are calculated for moment and angle:
• Mean value
• Standard deviation absolute
• Standard deviation percentages, based on mean value
• CP value / CPK value
The limits for the Cp/CPK value calculation can be entered. If no limits are set then the
calculation is done automatically with ±15 % of the mean value. The limits entered are
maintained even after switching off the sequence controller AST11.
The statistic can be displayed via the sequence controller AST11 as well as via the web
interface (also see
can be deleted for individual programs or completely for all programs.
The statistic is deleted when the sequence controller AST11 is switched off.
12.4 Print output
Data can be printed out in ASCII format via the serial data port of the AST40. The sum-
mary of the required values employs a format string template.
A format string can be summarized using random text and specified commands, whereby
texts can be output directly to the printer and commands can be replaced by the respective
valid value (see following table).
A command consisting of @ characters and ending with a blank character are shown for
this.
Changing the format string is only possible via the web-based user interface (see
). The print output is activated by the command "Print" during the screw-
driving process. Results of NOK screwdriving processes are always printed out.
The following commands are available:
Command
Output value
Output format
Example
date_euro
Date in Euro-format
Day.Month.Year
24.04.20013
date_usa
Date in US format
Month/Day/Year
04/24/20013
date_iso
Date in ISO format
Year-Month-Day
20013-04-24
time Time Hour:Minute:Second
7:13:37
AM
step Step
number
Value 3
torque
End torque Measuring
system 1
Value unit
0,215 Nm
angle
Angle measuring sys-
tem 1
Value unit
1080 °
prog Program
number
Value 1
errornum
Status / Error number
Value
0
errortext
Status / Error text
Error message
torque underrun
runtime
Running time
Value unit
0.5 s
torquetarget
Torque target value
Value unit
0.200 Nm
torqueLL
Torque lower limit
Value unit
0,000 Nm
torqueUL
Torque upper limit
Value unit
0,350 Nm
angletarget
Angle target value
Value unit
1080 degrees
angleLL
Angle lower limit
Value unit
1000 degrees
angleUL
Angle upper limit
Value unit
1150 degrees