Indications ............................................................................................................................................................ 3

1.1 Ultrasonic procedures
1.2 Air Polishing procedures

2

Contraindications and Warnings .......................................................................................................................... 3

2.1 Contraindications
2.2 Warnings

3

Precautions ....................................................................................................................................................... 3-4

3.1 Precautions for All Systems
3.2 Precautions for Ultrasonic Prophylaxis Procedures
3.3 Precautions for Airpolishing Procedures

4

Infection Control .................................................................................................................................................. 4

4.1 Infection Control Information Reference Card
4.2 General Infection Control Recommendations
4.3 Water Supply Recommendations

5

Installation Instructions .................................................................................................................................... 4-6

5.1 General Information
5.2 Water Line Requirements
5.3 Air Line Requirements and Recommendations
5.4 Electrical Requirements
5.5 Unpacking the System
5.6 Power Cord/Power Connection
5.7 Foot Control Cable Assembly Connection
5.8 Incoming Water Supply Line Connection
5.9 Air Supply Line Connection

6

Cavitron

 JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System .......................... 6-8

6.1 System Controls
6.2 Handpiece
6.3 Cavitron

®

 30K™ Ultrasonic Inserts

6.4 Cavitron™ JET Air Polishing Insert Nozzle
6.5 Foot Control Information and Operation
6.6 Operation for Ultrasonic Prophylaxis Prodedures
6.7 Operation for Air Polishing Prodedures

7

Accessories ............................................................................................................................................................ 9

7.1 Accessories List

8

Techniques for Use ......................................................................................................................................... 9-12

8.1 General Information on Patient Positioning
8.2 Performing Ultrasonic Scaling Procedures
8.3 Patient Comfort Considerations
8.4 Air Polishing Powder Chamber
8.5 Air Polishing using the JetShield™ Accessory
8.6 Performing JET Air Polishing Procedures with JetShield™
8.7 Performing Air Polishing Procedures without JetShield™
8.8 Proper Angulation of the Air Polishing Insert without JetShield™

9

System Care .................................................................................................................................................. 13-14

9.1 Daily Maintenance —Start-Up Procedures, Between Patients, Shut-Down Procedures
9.2 Periodic Maintenance

1 0

Troubleshooting ................................................................................................................................................ 1 4

10.1 Troubleshooting
10.2 Technical Support and Repairs

11

Specifications ..................................................................................................................................................... 1 5

12

Classifications .................................................................................................................................................... 15

Содержание Cavitron JET

Страница 1: ...oigneusement et compl tement avant d utiliser le syst me Por favor lea la totalidad de las instrucciones cuidadosamente antes de hacer funcionar la unidad Syst me combin Cavitron JET D tartreur ultras...

Страница 2: ...e insert s working tip This combined with acoustic effects of the coolant water produces a synergistic action that literally powers away the heaviest calculus deposits while providing exceptional oper...

Страница 3: ...nection 6 Cavitron JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System 6 8 6 1 System Controls 6 2 Handpiece 6 3 Cavitron 30K Ultrasonic Inserts 6 4 Cavitron JET Air Polishin...

Страница 4: ...Do not direct the air polishing stream at soft tissue or into the sulcus Tissue emphysema has been reportedly caused when the air water powder stream was directed at the soft tissues or into the sulc...

Страница 5: ...ystem s aerosol dispersion can be effectively controlled and minimized Please carefully follow the procedural guidelines in this manual regarding the use of your System For maximal operator and patien...

Страница 6: ...Specifications 5 7 Foot Control Cable Assembly Connection Align the Foot Control plug with the receptacle on the back of the System and push it in until firmly seated 5 5 Unpacking the System Carefull...

Страница 7: ...upply line to office air supply line or a Cavitron DualSelect dispensing System Inspect all connections to make certain there are no leaks Section 6 Cavitron Jet Combination System Ultrasonic Scaleran...

Страница 8: ...e automatically selects the JET mode when placed in handpiece Cleaning Powder Delivery Tube Directs air powder flow to insert tip Insert Heater Rod Heats the delivered water for patient comfort O Ring...

Страница 9: ...perationforUltrasonicProphylaxisProcedures No ultrasonic energy or lavage flow Ultrasonics and lavage flow are activated Foot control depressed all the way 6 7 Operation for Air Polishing Procedures F...

Страница 10: ...he rubber O ring on the insert with water before placing it into the handpiece Fully seat insert with a gentle push twist motion DO NOT FORCE Set the Unit s Power Adjustment knob to the lowest power s...

Страница 11: ...ing of the powder chamber An additional cap without a hole is provided for storage It is strongly recommended that the Powder Chamber be emptied at the end of each day This will reduce moisture absorp...

Страница 12: ...ly Pivot nozzle inside the cup to adapt to incisal gingival mesial and distal surfaces Apply two seconds of spray for each segment of the tooth releasing the Foot Control each time If spray escapes re...

Страница 13: ...t s head toward you to help prevent puddling in the cupped lip and minimize aerosol dispersion Use a saliva ejector or HVE In the posterior regions use the cheek to help contain aerosol spray 8 7 Perf...

Страница 14: ...ectant solution to air dry 5 If using a closed water supply check for adequate fluid volumes for next patient s scheduled treatment Shut Down Procedures at the end of the day 1 Turn the Unit OFF 2 Rem...

Страница 15: ...in the Foot Control Receptacle on the back of the System System operates No lavage flow at insert tip 1 Assure that Lavage control is properly adjusted 2 Check that irrigant supply control valve s de...

Страница 16: ...Weight 5 4 kg Dimensions Height 10 2 cm Width 18 7 cm Depth 24 1 cm Handpiece Cable 2 0 m Foot Control Cable 2 4 m Power Cord 2 1 m Water Supply Line 2 4 m Air Supply Line 2 5 m Footswitch Not for ope...