background image

SYMBOL DEFINITIONS:

Type B

Equipment

Dangerous

Voltage

Attention - Consult

Accompanying

Documents

17

Tulsa Dental Specialties warrants this product
against defects in material or workmanship for
a period of two (2) years, from date of original
invoice.  Handpieces are warranted for one
year under the same conditions.  Expendable
components such as light bulbs, are covered
by shorter warranty periods, or are not
warrantied. Tulsa Dental Specialties’ sole
obligation under product warranty is (at its
sole option and discretion) to repair or replace
any defective component or product in part or
whole.  Tulsa Dental Specialties shall be the
sole arbiter of such action.

In the event of alleged defect under warranty,
the purchaser is to notify Tulsa Dental
Specialties Customer Service Department
promptly.  Customer Service will provide
instructions, usually directing that the product
be returned for service.  Shipment to Tulsa
Dental Specialties and the cost thereof is
always the responsibility of the purchaser.

Accidental misuse, inappropriate installation,
or failure to perform directed maintenance
voids the warranty.

Tulsa Dental Specialties does not assume,
under this warranty, any risks or liabilities
arising from the clinical use of its products,
whether or not such use involves coincidental
utilization of products manufactured by others.

Tulsa Dental Specialties makes no warranty
other than that stated above, express or
implied.

WARRANTY:

The UL 2601 Standard Duty Cycle for Intermittent Use is 1 min.
on / 5 min. off.

MEDICAL EQUIPMENT WITH RESPECT
TO ELECTRIC SHOCK, FIRE AND
MECHANICAL HAZARDS ONLY IN
ACCORDANCE WITH UL 2601-1
CAN/CSA C22.2 No. 601.1

ISO 13485

0459

COMPLIES WITH 

DIRECTIVE 93/42/EEC

CONCERNING MEDICAL DEVICES

WARNING: This device has been tested and found
to comply with the emissions requirements of
EN 55011:1991.  These requirements provide
reasonable protection against harmful electro-
magnetic interference in a typical medical installation.
However, high levels of radio-frequency (RF)
emissions from electrical devices, such as cellular
phones, may disrupt the performance of this device.
To mitigate disruptive electromagnetic interference,
position this device away from RF transmitters and
other sources of electromagnetic energy.

AEU-25T Endodontic System

Distributed By: 

DENTSPLY Tulsa Dental Specialties

DENTSPLY International, Inc. 

608 Rolling Hills Drive 

Johnson City, TN 37604 

1-800-662-1202 • Fax: 1-800-597-2779

www.TulsaDentalSpecialties.com

Manufactured By:

Aseptico, Inc.

8333 216th St. SE

Woodinville, WA 98072, USA

Содержание AEU-25T

Страница 1: ...Endo DTC DIGITAL TORQUE CONTROL DUAL VOLTAGE AEU 25T Electronic Endodontic System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Страница 2: ...electric handpiece control system that is used in dentistry to drive endodontic files and instruments CONTRAINDICATIONS None Known WARNINGS Equipment not suitable for use in the presence of a flammabl...

Страница 3: ...se features combine to make the perfect rotary file system for endodontic and other dental procedures Congratulations This system is engineered to provide many years of reliable service Please read th...

Страница 4: ...e AE 4B 30 motor to the receptacle on the lower front panel of the console 4 Attach the E Type handpiece to the motor See Figure 2 5 Attach the supplied AE 7P On Off Foot Switch to the connector on th...

Страница 5: ...e Front Figure 4 Console Back Handpiece Ratio Selector Speed Selector Calibration System Setup PRESET MEMORY LOCK RECALL FACTORY SETUP AUTO STOP REVERSE REVERSE BEEPER TORQUE WARNING TONE ACCESSORY WA...

Страница 6: ...an endodontic rotary file into the handpiece 4 Use the Calibration function to calibrate the Endo DTC See Caution at right Press and release the CAL button The unit will run for a few seconds measuri...

Страница 7: ...sal S2 F1 File 3 ProTaper Universal F2 F3 F4 F5 File 4 ProTaper Universal Retreatment D1 D2 File 5 ProTaper Universal Retreatment D3 Preset Button 4 Default File Series DENTSPLY Tulsa Dental Specialti...

Страница 8: ...strument breakage is greatly reduced Torque settings are held in memory even after unit is turned off For most endodontic root canal applications the included 1 8 reduction contra angle handpiece is n...

Страница 9: ...To exit the System Setup Menu press 3 SAVE CHANGES selection will appear Select 1 to save changes and exit or select 2 to reject all changes and exit 6 CALIBRATION AND SYSTEM SETUP BUTTON Calibration...

Страница 10: ...dible when a GT Accessory file or ITR Emulation Accessory file is in use This is a system wide setting and is not saved on a Preset Button when programming To disable the Accessory Warning press 1 To...

Страница 11: ...e file series shown in Chart 1 on page 5 The Preset Buttons are also used to navigate the various menus in the System Setup and File Library The Preset Buttons can be customized to suit individual pre...

Страница 12: ...you have completed the customiza tion of the desired preset buttons re enable the Preset Memory Lock to avoid inadvertently entering the File Library during a procedure For instructions read about the...

Страница 13: ......

Страница 14: ...d inadvertently entering the File Library dur ing a procedure For instructions read about the System Setup Menu beginning on page 6 1 Disable the Preset Memory Lock For instructions read about the Sys...

Страница 15: ...ge 6 2 Set the Handpiece Ratio to the correct set ting Press the Handpiece Ratio Selector up or down arrows until the Handpiece Ratio Indicator matches the ratio of the handpiece to be used 3 Set the...

Страница 16: ...e from the motor and install plug as shown at right The included motor handpiece holding cradle is also fully autoclavable CONSOLE The exterior of the console may be cleaned by wiping with a soft clot...

Страница 17: ...voltage replace the fuses with fuses that are rated for the new voltage Turn the Fuse holder until the white lettering with the proper voltage is right side up 4 Replace the Fuse holder and close the...

Страница 18: ...5 volts 0 5A 250V slo blo fuse for 230 volts Check motor plug connection Check foot switch connection Depress foot switch Check that a file is properly seated in the handpiece and the latch is closed...

Страница 19: ...anty any risks or liabilities arising from the clinical use of its products whether or not such use involves coincidental utilization of products manufactured by others Tulsa Dental Specialties makes...

Страница 20: ...Johnson City TN 37604 1 800 662 1202 Fax 1 800 597 2779 www TulsaDentalSpecialties com Rx Only DFUDTC Rev 4 12 12 P N 420322 Rev J ECO 12954 12 12 Software P N 890002 Rev J TUL06 Series 2012 DENTSPLY...