9

2. If a Single File was programmed on the

preset button, the words "Single File
Preset" and the File Name will be dis-
played, as shown in the example below.

Preset Type

SINGLE FILE PRESET
PROTAPER S1 & SX

File Name

3. If a User Defined Preset was programmed

on the preset button, the words "User
Defined Preset" and the Handpiece Ratio,
Speed in RPM, and Torque in
Gram•Centimeters, will be displayed, as
shown in the example below.

Preset Type

USER DEFINED PRESET
1/8 AG        300         240

Ratio                  Speed          Torque

4. For all programming modes:

When the Endo DTC

®

is in operation (with

the foot pedal pressed), the Operation
Screen will be displayed. The Operation
Screen will show the Handpiece Ratio,
Speed (in RPM), Torque (in
Gram•Centimeters), Reverse Beeper (if
enabled), and Auto Stop Reverse (if
enabled).

Ratio                     Speed      Torque

1/8 AG           300     240
ASR  BPR    RPM   g-cm

{Auto Stop Reverse}  

{Reverse Beeper}

By default, the Preset Buttons are programmed
to recall the file series shown in Chart 1 on
page 5.

The Preset Buttons are also used to navigate
the various menus in the System Setup and
File Library.

The Preset Buttons can be customized to suit
individual preferences. There are three ways to
program a preset button.

The Preset Buttons can be programmed with:

1. An Entire File Series from the File Library

2. A Single File from the File Library

3. A User Defined Preset

When recalling a preset button, three different
displays will appear depending on how the pre-
set button was programmed:

1. If an Entire File Series was programmed

on the preset button (as is the case for
the factory default setup), the File Series
and File Name will be displayed, as
shown in the example below.

File Series

GT SERIES 20, 30, 40
ACC 90, 70, 50, 35/12

File Name #1

Pressing the same preset button again will
step to the next file in the file series, as
shown below.

File Series

GT SERIES 20, 30, 40
GT YEL 20/10 & 20/08

File Name #2

8.

INTRODUCTION TO PROGRAMMING PRESET BUTTONS:

NOTE: When PRO-POST DRILLS  is selected, there will not be a prompt for “LOAD ENTIRE SERIES”
because there is only one selection.

*

*

Содержание AEU-25T

Страница 1: ...Endo DTC DIGITAL TORQUE CONTROL DUAL VOLTAGE AEU 25T Electronic Endodontic System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Страница 2: ...electric handpiece control system that is used in dentistry to drive endodontic files and instruments CONTRAINDICATIONS None Known WARNINGS Equipment not suitable for use in the presence of a flammabl...

Страница 3: ...se features combine to make the perfect rotary file system for endodontic and other dental procedures Congratulations This system is engineered to provide many years of reliable service Please read th...

Страница 4: ...e AE 4B 30 motor to the receptacle on the lower front panel of the console 4 Attach the E Type handpiece to the motor See Figure 2 5 Attach the supplied AE 7P On Off Foot Switch to the connector on th...

Страница 5: ...e Front Figure 4 Console Back Handpiece Ratio Selector Speed Selector Calibration System Setup PRESET MEMORY LOCK RECALL FACTORY SETUP AUTO STOP REVERSE REVERSE BEEPER TORQUE WARNING TONE ACCESSORY WA...

Страница 6: ...an endodontic rotary file into the handpiece 4 Use the Calibration function to calibrate the Endo DTC See Caution at right Press and release the CAL button The unit will run for a few seconds measuri...

Страница 7: ...sal S2 F1 File 3 ProTaper Universal F2 F3 F4 F5 File 4 ProTaper Universal Retreatment D1 D2 File 5 ProTaper Universal Retreatment D3 Preset Button 4 Default File Series DENTSPLY Tulsa Dental Specialti...

Страница 8: ...strument breakage is greatly reduced Torque settings are held in memory even after unit is turned off For most endodontic root canal applications the included 1 8 reduction contra angle handpiece is n...

Страница 9: ...To exit the System Setup Menu press 3 SAVE CHANGES selection will appear Select 1 to save changes and exit or select 2 to reject all changes and exit 6 CALIBRATION AND SYSTEM SETUP BUTTON Calibration...

Страница 10: ...dible when a GT Accessory file or ITR Emulation Accessory file is in use This is a system wide setting and is not saved on a Preset Button when programming To disable the Accessory Warning press 1 To...

Страница 11: ...e file series shown in Chart 1 on page 5 The Preset Buttons are also used to navigate the various menus in the System Setup and File Library The Preset Buttons can be customized to suit individual pre...

Страница 12: ...you have completed the customiza tion of the desired preset buttons re enable the Preset Memory Lock to avoid inadvertently entering the File Library during a procedure For instructions read about the...

Страница 13: ......

Страница 14: ...d inadvertently entering the File Library dur ing a procedure For instructions read about the System Setup Menu beginning on page 6 1 Disable the Preset Memory Lock For instructions read about the Sys...

Страница 15: ...ge 6 2 Set the Handpiece Ratio to the correct set ting Press the Handpiece Ratio Selector up or down arrows until the Handpiece Ratio Indicator matches the ratio of the handpiece to be used 3 Set the...

Страница 16: ...e from the motor and install plug as shown at right The included motor handpiece holding cradle is also fully autoclavable CONSOLE The exterior of the console may be cleaned by wiping with a soft clot...

Страница 17: ...voltage replace the fuses with fuses that are rated for the new voltage Turn the Fuse holder until the white lettering with the proper voltage is right side up 4 Replace the Fuse holder and close the...

Страница 18: ...5 volts 0 5A 250V slo blo fuse for 230 volts Check motor plug connection Check foot switch connection Depress foot switch Check that a file is properly seated in the handpiece and the latch is closed...

Страница 19: ...anty any risks or liabilities arising from the clinical use of its products whether or not such use involves coincidental utilization of products manufactured by others Tulsa Dental Specialties makes...

Страница 20: ...Johnson City TN 37604 1 800 662 1202 Fax 1 800 597 2779 www TulsaDentalSpecialties com Rx Only DFUDTC Rev 4 12 12 P N 420322 Rev J ECO 12954 12 12 Software P N 890002 Rev J TUL06 Series 2012 DENTSPLY...

Отзывы: