53
TEST FOR AIR LEAKS
1.
Close shut-off valve
(FIGURE 45)
.
2. Run compressor until it shuts off with a tank pressure
of 115 PSI/793 kPa showing on the Home screen of the
control panel LDC display
(FIGURE 46)
.
3. On the Technical screen, press and enable
MAINTENANCE MODE (FIGURE 47)
.
NOTE:
Turning on maintenance mode disables remote
switching and puts the system in standby mode.
4. Let compressor sit for 5 minutes.
5. On the Home screen, check tank pressure. If the
pressure drop is more than 5 PSI/34kPa in a 5-minute
time period, leaks must be repaired. Repair if needed.
6. Open shut-off valve.
MAINTENANCE (CONTINUED)
SECTION V - CARE
FIGURE 45. CLOSE SHUT-OFF VALVE
SHUT-OFF
VALVE
(CLOSED)
FIGURE 46. RUN COMPRESSOR TO 115 PSI SHUTOFF
07:33:14 PM
LTE
Settings
Technical
Info
Home
20 hrs
Equipment Runtime
71.3 F
Ambient Temp
-40.0 F
Pressure Dew Point
115 PSI
Tank Pressure
On
FIGURE 47. ENABLE MAINTENANCE MODE
Service
Runtimes
Sensors
Motors
Alerts
High Pressure Mode
Maintenance Mode
07:33:14 PM
Maintenance Mode
LTE
Settings
Technical
Info
Home
Network
(Continued on the next page.)