14
COMPRESSOR USER MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-004A
NON-ILLUMINATED REMOTE SWITCHES
Non-illuminated switches provide no
indication for system status.
ILLUMINATED REMOTE PANELS
Switch light is steady on when system is running normally.
Switch light flashes for maintenance or one of the heads has
been disabled by the disable button on the control panel.
Recommended Switching
Alternative Switching
Toggle Switch
or Other Non-
Illuminated
Switch
(Option)
Aeras
Control
Terminals
F
H
Air Switch
+24V DC
+24V DC
DC Common
F
G
H
Air Light
Common
Ramvac
Remote
Panel (or
Equivalent)
with
Illuminated
24V DC
Switch
Aeras
Control
Terminals
F
H
G
1
2
3
AIR
LOW-VOLTAGE REMOTE SWITCHING
NOTICE
Maximum wire length for 18-gauge wire is 500 feet.
Low-voltage remote switching is used to turn the system on and off from a remote location. Your Aeras compressor is
manufactured to continuously cycle as required throughout the workday. Power the compressor off at end of day.
LOW-VOLTAGE WIRING CONNECTIONS (CONTINUED)
SECTION III - INSTALLATION
AERAS CONTROL PANEL
REMOTE
SWITCH
FGH
CONNECTOR
(Continued on the next page.)