8.5.3
Removing the chain collector box
Fig. 38
–
Unscrew and remove service cover (1).
–
Place bag (2) with the control cable on the top of the chain hoist.
–
Disconnect spring (3) and place it in the recess in the chain collector box.
–
Remove retaining spring (4) from pin (5) and remove the pin. While doing so, hold the chain collector.
–
Place chain collector box (6) on the ground.
8.5.4
Operating limit switches (standard for DC-Com 10 with 2/1 reeving)
8.5.4.1
Checking operating limit switches
DANGER
Danger of broken chain and falling load
The chain may break and loads may fall if the emergency limit position limiter is frequently approached.
214