D V S M a n a g e d I n d u s t r i a l R a c k Mo u n t E t h e r n e t S wi t c h U s e r Ma n u a l
3 - 8 6
Description
Factory default
Specify the MAC mask that is associated with the destination MAC address. The MAC
mask specifies the bits in the destination MAC address which need to be compared
with the information in a packet.
Note:
Use zeros and Fs in the MAC mask. An F means that the bit is not
checked, and a zero in a bit position means that the data needs to be equal
to the value given to that bit. For example, if the MAC address is
aa:bb:cc:dd:ee:ff, and the mask is 00:00:ff:ff:ff:ff, all MAC addresses with
aa:bb:xx:xx:xx:xx result in a match (where x is any hexadecimal number).
None
EtherType Key
Specify the EtherType that needs to be compared with the information in a packet:
Appletalk, ARP, IBM SNA, IPv4, IPv6, IPX, MPLS multicast, MPLS unicast,
NetBIOS, Novell, PPPoE, Reverse ARP, EthernCAT, Profinet-RT, SERCOS III,
CC-link IE, Powerlink, User Value
.
If you select User Value, enter the value in the EtherType User Value field.
None
EtherType User Value
If you select User Value from the EtherType Key drop-down list, enter the value, which
is a number in the range of 1536 to 65535.
None
Source MAC
Specify the MAC address of the source device that needs to be compared with the
information in a packet. Enter a MAC address in the xx:xx:xx:xx:xx:xx format.
None
Source MAC Mask
As an option, specify the MAC mask that is associated with the source MAC address.
The MAC mask specifies the bits in the source MAC address which need to be
compared with the information in a packet.
Note:
Use zeros and Fs in the MAC mask.An F means that the bit is not checked,
and a zero in a bit position means that the data needs to be equal to the
value given to that bit. For example, if the MAC address is aa:bb:cc:dd:ee:ff,
and the mask is 00:00:ff:ff:ff:ff, all MAC addresses with aa:bb:xx:xx:xx:xx
result in a match (where x is any hexadecimal number).
None
VLAN
Specify the VLAN ID that needs to be compared with the information in a packet.
Enter a number in the range of 0 to 4095. You can not enter a VLAN range.
Note:
Most VLAN configurations on the switch are in the range of 1 to 4093.
However, an ACL can detect a VLAN in the range of 0 to 4095.
None
Содержание DVS-328 series
Страница 8: ...vii ...
Страница 13: ...Chapter 1 Introduction 1 5 MEMO ...
Страница 21: ...DVS Managed Industrial Rack mount Ethernet Switch User Manual 2 8 MEMO ...
Страница 64: ...Chapter 3 Featured Functions 3 43 ...
Страница 69: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 48 3 3 1 3 CST Port Configuration ...
Страница 161: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 140 MEMO ...
Страница 172: ...A 1 Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 ...
Страница 245: ...D 1 Appendix D EDS File Table of Contents D 1 EDS Electronic Data Sheet File D 2 ...