Multiple Port Mirroring
Description
Factory default
Monitored Port
Specify the monitored port or ports for the monitoring.
Unchecked
Session Mode
Specify whether the port mirroring session mode is enabled:
Enable:
The port mirroring is enabled. The setting applies to all interfaces.
Disable:
The port mirroring is disabled. The setting applies to all interfaces.
Note:
When you configure the session mode for an individual interface, it is
applied to all interfaces. You can select
Enable
from the Session Mode
drop-down list and control the port mirroring for individual interfaces. If you
want to disable the port mirroring, make sure that the direction is not
configured for the interfaces. If the direction is configured for the interfaces
and you want to disable the port mirroring, select the check box of the
interface, and click
Delete
to remove the port mirroring configuration for the
interface.
None
Watch Direction
Specify the direction in which the port mirroring occurs:
Tx and Rx:
Both outgoing traffic and incoming traffic are mirrored.
Tx Only:
Only outgoing traffic is mirrored.
Rx Only:
Only incoming traffic is mirrored.
None
Mirror Port
Specify the port which is the mirror port.
None
Status Table
Item
Description
Monitored Port
This field displays the monitored port number.
Mirror Port
This field displays the destination port or the monitored interface. Only one port
can be the mirror port. This port is used as the mirror port for all ports which you
configure for the port mirroring.
Session Mode
The port mirroring status of the port.
Enable:
The port mirroring is enabled.
Disable:
The port mirroring is disabled.
Direction
The direction of the port mirroring.
Tx and Rx:
Both outgoing traffic and incoming traffic are mirrored.
Tx Only:
Only outgoing traffic is mirrored.
Rx Only:
Only incoming traffic is mirrored.
Содержание DVS-328 series
Страница 8: ...vii ...
Страница 13: ...Chapter 1 Introduction 1 5 MEMO ...
Страница 21: ...DVS Managed Industrial Rack mount Ethernet Switch User Manual 2 8 MEMO ...
Страница 64: ...Chapter 3 Featured Functions 3 43 ...
Страница 69: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 48 3 3 1 3 CST Port Configuration ...
Страница 161: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 140 MEMO ...
Страница 172: ...A 1 Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 ...
Страница 245: ...D 1 Appendix D EDS File Table of Contents D 1 EDS Electronic Data Sheet File D 2 ...