C h a p t e r 3 F e a t u r e d F u n c t i o n s
3 - 11 5
Description
Factory default
Severity
Specify the level of the severity that determines which events are logged. A log
records the messages equal to or above a configured severity threshold. For
example, if you select an error, the logged messages include error (3), critical
(2), alert (1), and emergency (0). The default level of the severity is critical (2).
Make a selection from the drop-down list:
emergency:
The highest warning level (level 0). An emergency message is
saved if the switch is down or not functioning correctly.
alert:
The second-highest warning level (level 1). An alert message is
saved if there is a serious switch malfunction, for example, an important
switch function goes down. Action needs to be taken immediately.
critical:
The third-highest warning level (level 2). A critical message is
saved if a critical switch malfunction occurs, for example, two interfaces
stop functioning while the rest of the interfaces remain functional.
error:
The level that indicates that a device error has occurred (level 3),
such as an interface going offline
warning:
The lowest level of a device warning (level 4).
notice:
Normal but significant conditions (level 5). Provides the network
administrators with the switch information.
Informational:
Provides the switch information (level 6).
debug:
Provides the detailed information about the switch (level 7). This
level generates a lot of messages.
critical
Logging filesize
Specify the size of the system file in which the log files are saved. Enter a file
size between 1024 and 102400 bytes.
Note:
The debug log file is not controlled by the size of the system file.
The debug log file is a temporary file that is not stored in the flash
memory. The file can always store the most recent 100 debug log
messages, and each debug log message is less than 80 bytes in
length.
10240
3.12.7.3
Syslog Fwd Table
You can add the syslog server IP address and configure the forward log severity on this page.
Содержание DVS-328 series
Страница 8: ...vii ...
Страница 13: ...Chapter 1 Introduction 1 5 MEMO ...
Страница 21: ...DVS Managed Industrial Rack mount Ethernet Switch User Manual 2 8 MEMO ...
Страница 64: ...Chapter 3 Featured Functions 3 43 ...
Страница 69: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 48 3 3 1 3 CST Port Configuration ...
Страница 161: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 140 MEMO ...
Страница 172: ...A 1 Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 ...
Страница 245: ...D 1 Appendix D EDS File Table of Contents D 1 EDS Electronic Data Sheet File D 2 ...