D V S M a n a g e d I n d u s t r i a l R a c k Mo u n t E t h e r n e t S wi t c h U s e r Ma n u a l
3 - 1 3 2
Description
Factory default
Disable:
Disable ONE RING, ONE CHAIN, or ONE COUPLING event to trigger
relay alarm 1 or 2.
Enable:
Enable ONE RING, ONE CHAIN, or ONE COUPLING event to trigger relay
alarm 1 or 2.
Note:
If the hardware version is too old, this function will not be activated.
Port Events
Description
Factory default
Link
Specify the port link event status:
Disable:
Disable the port link to trigger relay alarm 1 or 2.
On to Off:
When the status of the port link changes from On to Off, relay alarm 1 is
triggered.
Off to On:
When the status of the port link changes from Off to On, relay alarm 1 is
triggered.
Disable
Traffic-Overload
Specify the traffic overload event status. The traffic overload is used to monitor the
port’s
ingress
traffic flow. It has two parameters: threshold and duration.
Disable:
Disable traffic-overload to trigger relay alarm 1 or 2.
Enabled:
Enable traffic-overload to trigger relay alarm 1 or 2.
Disable
Traffic-Threshold (%)
Specify the traffic speed threshold percentage of the port. Enter the value between 1
and 100.
1
Traffic-Duration (s)
Specify the traffic overload duration. If the average flow of the port overloads the
threshold during this duration, it means the traffic is overloaded. Enter the value
between 1 and 300.
1
Note:
If you want the Relay Alarm function to work properly, please make sure that the Delta switch has
one set of power at least
.
For example:
The Power 1 system event is configured to “Off to On”, and Power 1 & 2 have no power. If you
provide power for Power 1, then Relay Alarm will not be triggered. Because when the event
happened, the Delta switch has no power at that moment.
The Power 1 system event is configured to “On to Off”, and Power 1 has power, but Power 2 has
no power. If you turn off Power 1, then Relay Alarm will not be triggered. Even though the Delta
switch has power at the moment when the event happens, it has no power after that moment, so
Relay Alarm will not be triggered.
3.14.1.2
Relay Alarm Table
The status of Relay Alarm is displayed on this page. This table only displays the current alarm, so if the event is
not triggered, it is not displayed either.
Содержание DVS-328 series
Страница 8: ...vii ...
Страница 13: ...Chapter 1 Introduction 1 5 MEMO ...
Страница 21: ...DVS Managed Industrial Rack mount Ethernet Switch User Manual 2 8 MEMO ...
Страница 64: ...Chapter 3 Featured Functions 3 43 ...
Страница 69: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 48 3 3 1 3 CST Port Configuration ...
Страница 161: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 140 MEMO ...
Страница 172: ...A 1 Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 ...
Страница 245: ...D 1 Appendix D EDS File Table of Contents D 1 EDS Electronic Data Sheet File D 2 ...