Loopback-Detection Global Configuration
Description
Factory default
Module Status
Specify whether the status in global configuration is activated or not.
Enable
3.1.9.2
Port Configuration
The parameters of Loopback-Detection should be set for each port.
Notice:
If you need to configure Loopback-Detection Port Configuration, you must enable the
Loopback-Detection Global mode.
Loopback-Detection Port Configuration
Description
Factory default
Interface
The interface number.
interface number
Port Control
Enable/Disable the Loopback-Detection feature on the port.
Disable
Recovery Mode
There are two recovery modes for recovering the blocking port. Loops occur as the
reason for blocking the port.
Auto Mode
: After the port is blocked, the port will be automatically linked up after a
recovery interval.
Manual Mode
: After the port is blocked, we have to manually enable the port.
Follow Basic Setting > Port Setting > Port Settings (Admin Mode) to enable the
blocking port.
Manual
Recovery Interval
In Auto Mode, the blocking port will be linked up after a recovery interval. The unit is a
second and the range is between 30 and 38400.
300
Содержание DVS-328 series
Страница 8: ...vii ...
Страница 13: ...Chapter 1 Introduction 1 5 MEMO ...
Страница 21: ...DVS Managed Industrial Rack mount Ethernet Switch User Manual 2 8 MEMO ...
Страница 64: ...Chapter 3 Featured Functions 3 43 ...
Страница 69: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 48 3 3 1 3 CST Port Configuration ...
Страница 161: ...DVS Managed Industrial Rack Mount Ethernet Switch User Manual 3 140 MEMO ...
Страница 172: ...A 1 Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 ...
Страница 245: ...D 1 Appendix D EDS File Table of Contents D 1 EDS Electronic Data Sheet File D 2 ...