PMAC Quick Reference Guide
18
PMAC Executive Program, PEWIN
Sluggish Response
Cause: Too much damping or too little proportional gain
Fix: Increase
K
P
(Ix30) or decrease K
D
(Ix31)
Overshoot and Oscillation
Cause: Too little damping or too much proportional gain
Fix: Decrease
K
P
(Ix30) or increase K
D
(Ix31)
4. Perform a parabolic move and use the following guidelines for the selection of the appropriate I-
Variables:
Ideal Case
The following error is reduced at
minimum and is concentrated in the
center, evenly along the move
High vel \ FE correlation
Cause: damping
Fix: Increase
K
vel
(Ix32)
High vel \ FE correlation
Cause: friction
Fix:
Increase Integral gain (Ix33) or
Friction Feedforward (Ix68)
High acc \ FE correlation
Cause: Integral
lag
Fix: Increase
K
aff
(Ix35)
High acc \ FE correlation
Cause: Physical
system
limitations
Fix:
Use less sudden acceleration
Negative vel \ FE correlation
Cause:
Too much velocity FF
Fix: Decrease
K
vel
(Ix32)
High vel \ FE correlation
Cause: damping and friction
Fix: Increase
K
vel
(Ix32)
High acc \ FE correlation
Cause:
Too much acc FF
Fix: Decrease
K
aff
(Ix35)
High vel\FE and acc\FEcorrelation
Cause:
Integral lag and friction
Fix: Increase
K
aff
(Ix35)
Содержание PMAC Mini
Страница 4: ......
Страница 8: ...PMAC Quick Reference Guide iv Table of Contents ...
Страница 28: ...PMAC Quick Reference Guide 20 PMAC Executive Program PEWIN ...
Страница 80: ...PMAC Quick Reference Guide 72 Troubleshooting ...
Страница 82: ...PMAC Quick Reference Guide 74 Appendix A PMAC Error Code Summary ...
Страница 88: ...PMAC Quick Reference Guide 80 Appendix B PMAC I Variables Summary ...
Страница 106: ...PMAC Quick Reference Guide 98 Appendix F I O Suggested M Variable Definitions ...