PMAC Quick Reference Guide
Appendix B – PMAC I-Variables Summary
77
Motor Safety I-Variables Range
Default
Units
Ix11 Motor x Fatal Following Error
Limit
0 .. 8,388,607
32000
1/16 Count
Ix12 Motor x Warning Following Error
Limit
0 .. 8,388,607
16000
1/16 Count
Ix13 Motor x + Software Position Limit
± 247
0 (Disabled) Encoder Counts
Ix14 Motor x - Software Position Limit
± 247
0 (Disabled) Encoder Counts
Ix15 Motor x Abort/Lim Decel Rate
Positive floating
point
0.25 Counts/msec2
Ix16 Motor x Maximum Velocity
Positive floating
point
32 Counts/msec
Ix17 Motor x Maximum Acceleration Positive
floating
point
0.015625 Counts/msec2
Ix19 Motor x Maximum Jog
Acceleration
Positive floating
point
0.015625 Counts/msec2
Motor Movement I-Variables
Range
Default
Units
Ix20 Motor x Jog/Home Acceleration
Time
0 .. 8,388,607
0 (so Ix21
controls)
Msec
Ix21 Motor x Jog/Home S-Curve Time
0 .. 8,388,607
50
Msec
Ix22 Motor x Jog Speed
Positive floating
point
32
Counts / msec
Ix23 Motor x Homing Speed &
Direction
Floating point
32
Counts / msec
Ix25 Motor x Flag Address
PMAC X
addresses
See Ix25 table Extended legal PMAC X addresses
Ix26 Motor x Home Offset
-8,388,608 ..
8,388,607
0 1/16
Count
Ix27 Motor x Position Rollover Range
0 .. 8,388,607
0
Counts
Ix28 Motor x In-Position Band
0 .. 8,388,607
160 (=10
counts)
1/16 Count
Ix29 Motor x DAC/1st Phase Bias
-32,768 .. 32,767
0
DAC Bits
Servo Control I-Variables
Range
Default
Units
Ix30 Motor x Proportional Gain
-8,388,608 ..
8,388,607
2000
(Ix08/219) DAC bits/Encoder count
Ix31 Motor x Derivative Gain
-8,388,608 ..
8,388,607
1280 (Ix30*Ix09)/226
DAC
bits/(Counts/cycle)
Ix32 Motor x Velocity Feed Forward
Gain
0 .. 8,388,607
1280
(Ix30*Ix08)/226 DAC
bits/(Counts/cycle)
Ix33 Motor x Integral Gain
0 .. 8,388,607
0
(Ix30*Ix08)/242 DAC
bits/(counts*cycles)
Ix34 Motor x Integration Mode
0 .. 1
1
none
Ix35 Motor x Acceleration Feed
Forward Gain
0 .. 8,388,607
0
(Ix30*Ix08)/226 DAC
bits/(counts/cycle2)
Ix36 Motor x PID Notch Filter
Coefficient N1
-2.0 .. +2.0
0
none (actual z-transform coefficient)
Ix37 Motor x PID Notch Filter
Coefficient N2
-2.0 .. +2.0
0
none (actual z-transform coefficient)
Ix38 Motor x PID Notch Filter
Coefficient D1
-2.0 .. +2.0
0
none (actual z-transform coefficient)
Ix39 Motor x PID Notch Filter
Coefficient D2
-2.0 .. +2.0
0
none (actual z-transform coefficient)
Ix40-
Ix56
Motor x Extended Servo Loop I-
Variable
Содержание PMAC Mini
Страница 4: ......
Страница 8: ...PMAC Quick Reference Guide iv Table of Contents ...
Страница 28: ...PMAC Quick Reference Guide 20 PMAC Executive Program PEWIN ...