Power Brick Controller User Manual
Connections and Software Setup
65
Serial Data Registers
– Mitutoyo
The resulting position data, status, and error bits for Mitutoyo are found in the following Serial Data
Registers:
PowerBrick[
i
].Chan[
j
].SerialEncDataA
Possible Single-Turn/Multi-turn Position
PowerBrick[
i
].Chan[
j
].SerialEncDataB
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Status Field
Alarm code
Encoder ID
Bit #
Alarm Code
16
Initialization error
17
Mismatch of optical and capacitive sensors
18
Optical sensor error
19
Capacitive sensor error
20
CPU error (AT303); CPU/ROM/RAM error (AT503)
21
EEPROM error
22
ROM/RAM error (AT303); communication error (AT503)
23
Overspeed error
Bit #
Status Field
24
Fatal (unrecoverable) encoder error
25
–
26
Illegal command code from controller
27
–
Ti
m
e
out
E
rr
.
C
R
C
E
rr
.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Содержание PBC Series
Страница 5: ......
Страница 74: ...Power Brick Controller User Manual Connections and Software Setup 74 Motor 1 HomeOffset 0...
Страница 203: ...Power Brick Controller User Manual Appendix A Digital Inputs Schematic 203 APPENDIX A DIGITAL INPUTS SCHEMATIC...
Страница 204: ...Power Brick Controller User Manual Appendix B Digital Outputs Schematic 204 APPENDIX B DIGITAL OUTPUTS SCHEMATIC...
Страница 205: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 205 APPENDIX C ANALOG I OS SCHEMATICS...
Страница 206: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 206...
Страница 207: ...Power Brick Controller User Manual Appendix D Limits Flags Schematic 207 APPENDIX D LIMITS FLAGS SCHEMATIC...