Serial Data Registers
– Panasonic
The resulting position data, status, and error bits for Panasonic are found in the following Serial Data
Registers.
PowerBrick[
i
].Chan[
j
].SerialEncDataA
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Multi-Turn Position
Or
Encoder ID Code
Single-Turn Position
PowerBrick[
i
].Chan[
j
].SerialEncDataB
Status Field
Alarm code
when commanded
Multi-Turn Position
Or
Encoder ID Code
Bits 24 – 31 (SerialEncDataA) of the encoder ID code are fixed at a value of $11.
Bit #
Alarm Code
8
Overspeed error
9
Full resolution status; = 1 when over 100 rpm and reporting reduced resolution
10
Count Error
11
Counter Overflow
12
–
13
Multi-revolution error
14
System undervoltage error (< 2.5 VDC)
15
Battery low (< 3.1 VDC)
Ti
m
e
out
E
rr
.
C
R
C
E
rr
.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Содержание PBC Series
Страница 5: ......
Страница 74: ...Power Brick Controller User Manual Connections and Software Setup 74 Motor 1 HomeOffset 0...
Страница 203: ...Power Brick Controller User Manual Appendix A Digital Inputs Schematic 203 APPENDIX A DIGITAL INPUTS SCHEMATIC...
Страница 204: ...Power Brick Controller User Manual Appendix B Digital Outputs Schematic 204 APPENDIX B DIGITAL OUTPUTS SCHEMATIC...
Страница 205: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 205 APPENDIX C ANALOG I OS SCHEMATICS...
Страница 206: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 206...
Страница 207: ...Power Brick Controller User Manual Appendix D Limits Flags Schematic 207 APPENDIX D LIMITS FLAGS SCHEMATIC...