Configuring Quadrature Encoders
The Power Brick Controller default settings are configured for quadrature encoders. Minimal setup is
required to configure them; quadrature encoder signals are processed as a single 32-bit read in the encoder
conversion table (ECT). 1/T extension is done in the Gate3 "hardware".
The default ECT settings for an incremental quadrature encoder look like:
Note
The hardware 1/T extension produces 8 bits of fractional data, thus
the (1 / 256) 0.00390625 scale factor.
Channel
Number
Quadrature Encoder
Source Address
Channel
Number
Quadrature Encoder
Source Address
1
PowerBrick[0].Chan[0].ServoCapt.a
5
PowerBrick[1].Chan[0].ServoCapt.a
2
PowerBrick[0].Chan[1].ServoCapt.a
6
PowerBrick[1].Chan[1].ServoCapt.a
3
PowerBrick[0].Chan[2].ServoCapt.a
7
PowerBrick[1].Chan[2].ServoCapt.a
4
PowerBrick[0].Chan[3].ServoCapt.a
8
PowerBrick[1].Chan[3].ServoCapt.a
Activating the corresponding channel is sufficient to display counts in the position window when the motor
/ encoder shaft is moved by hand.
The position and velocity source(s) must be pointing to the proper ECT result. With quadrature encoders,
they are initiated by the firmware:
Counts per User Units
With quadrature encoders, the number of counts per user units (usually revolution) is 4 times the specified
number of lines of the encoder. For example, a 1,000–line rotary encoder should result in 4,000 motor units
per revolution.
EncTable[
1
].type =
1
// Single 32-bit read
EncTable[
1
].pEnc = PowerBrick[
0
].Chan[
0
].ServoCapt.a
// Primary source, ch 1 Servo Capture
EncTable[
1
].pEnc1 = Sys.Pushm
// Secondary source, none
EncTable[
1
].index1 =
0
// left shift, none
EncTable[
1
].index2 =
0
// right shift, none
EncTable[
1
].index3 =
0
//
EncTable[
1
].index4 =
0
//
EncTable[
1
].ScaleFactor =
1
/
256
// Scale Factor, LSB location
Motor[
1
].ServoCtrl =
1
// Channel activation
Motor[
1
].pEnc = EncTable[
1
].a
// Position
Motor[
1
].pEnc2 = EncTable[
1
].a
// Velocity
Содержание PBC Series
Страница 5: ......
Страница 74: ...Power Brick Controller User Manual Connections and Software Setup 74 Motor 1 HomeOffset 0...
Страница 203: ...Power Brick Controller User Manual Appendix A Digital Inputs Schematic 203 APPENDIX A DIGITAL INPUTS SCHEMATIC...
Страница 204: ...Power Brick Controller User Manual Appendix B Digital Outputs Schematic 204 APPENDIX B DIGITAL OUTPUTS SCHEMATIC...
Страница 205: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 205 APPENDIX C ANALOG I OS SCHEMATICS...
Страница 206: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 206...
Страница 207: ...Power Brick Controller User Manual Appendix D Limits Flags Schematic 207 APPENDIX D LIMITS FLAGS SCHEMATIC...