Power Brick Controller User Manual
Manual Motor Setup
123
Direct Digital PWM Output
Having performed the following:
Global Reset (optional but recommended).
Set up the dominant clock frequencies.
Unpacked the ADC input and phase output data.
Verified encoder feedback.
Caution
If the +24 VDC abort input is not wired in or disabled in software
(
Sys.pAbortAll = 0
), PMAC will try to close the loop on the motor
every time it is enabled which could cause the motor the move or jump
(if it has not been set up).
The abort input must be wired in (+24 VDC) or disabled in software (
Sys.pAbortAll = 0
) prior to attempting
to enable the motor.
If the +24 VDC abort input is not wired in or is not disabled in software (
Sys.pAbortAll = 0
), PMAC will
try to close the loop on the motor every time it is enabled. This could prevent setting up a motor properly,
such as phasing manually or performing an open loop test
Motor and channel specific parameters can now be configured to finalize the setup procedure.
Note
A motor or channel parameter which is not discussed in the structure
elements below is assumed – and should typically be left – at default.
Содержание PBC Series
Страница 5: ......
Страница 74: ...Power Brick Controller User Manual Connections and Software Setup 74 Motor 1 HomeOffset 0...
Страница 203: ...Power Brick Controller User Manual Appendix A Digital Inputs Schematic 203 APPENDIX A DIGITAL INPUTS SCHEMATIC...
Страница 204: ...Power Brick Controller User Manual Appendix B Digital Outputs Schematic 204 APPENDIX B DIGITAL OUTPUTS SCHEMATIC...
Страница 205: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 205 APPENDIX C ANALOG I OS SCHEMATICS...
Страница 206: ...Power Brick Controller User Manual Appendix C Analog I Os Schematics 206...
Страница 207: ...Power Brick Controller User Manual Appendix D Limits Flags Schematic 207 APPENDIX D LIMITS FLAGS SCHEMATIC...