background image

DeviceNet Slave Communication Module IFD9502

 

 

DVP-PLC Application Manual

 

10 

3.2  When IFD9502 is connected to Delta DVP series programmable logic controller 

 

DeviceNet

RS-485 communication

Delta DVP series PLC

DVP28SV

DVPDNET-SL

DVPDNET

DVP28SV

RUN

STOP

Master

 

1.  Baud rate and the setting of communication format 

Before connecting the PLC to bus, set the node address of PLC as 01 and the communication format as 

115,200 bps; 7, E, 1; ASCII (the format is fixed; other formats will be invalid). 

2.  Class 0x96 parameter 

z

 Instance0

 

Attribute ID 

Access rule 

Name 

Data type 

1 Get 

Revision 

UINT 

z

 

Instance1 through 9 

Instance ID 

Description 

S device of PLC 

X device of PLC 

Y device of PLC 

M device of PLC 

T device of PLC (bit device) 

T device of PLC (word device) 

C device of PLC (bit device) 

C device of PLC (word device) 

D device of PLC 

All Instances in the table do not support any Attribute. 

Содержание DeviceNet Slave Communication Module IFD9502

Страница 1: ...IFD9502 DeviceNet Slave Communication Module Application Manual...

Страница 2: ......

Страница 3: ...O terminals otherwise serious damage may occur Check all the wirings again before switching on the power and DO NOT touch any terminal when the power is switched on Make sure the ground terminal is co...

Страница 4: ...DVP PLC Application Manual 2 5 1 DeviceNet Object 27 6 CONNECTION OF IFD9502 WITH OTHER EQUIPMENT 38 6 1 Communication Wirings When Connected to Equipment Through PORT 1 38 6 2 Communication Wirings W...

Страница 5: ...us between IFD9502 and the equipments For more details on LED indicators see 12 4 2 IFD9502 sets up its node address in DeviceNet by two rotary switches For more details on the switches see 12 2 3 Fun...

Страница 6: ...0Hz 2 Components 2 1 Product Profile and Outline Unit mm 1 Communication ports 6 MS Module Status indicator 2 Address setup rotary switches 7 NS Network Status indicator 3 Function setup DIP switches...

Страница 7: ...is to be used on the equipment connected to IFD9502 the selection of communication ports and setting up the baud rate of IFD9502 and the master in DeviceNet 1 2 3 4 5 6 7 8 SW3 DIP ON 1 Selecting equi...

Страница 8: ...ating changing the baud rate will be invalid 2 5 Communication ports on IFD9502 The communication ports on IFD9502 are used for the connection with the equipment Delta programmable logic controller De...

Страница 9: ...ration software When the configuration software is used for modifying a parameter in AC motor drive IFD9502 will read the maximum value minimum value and read write attribute of the parameter and deci...

Страница 10: ...preset as 2 words at addresses H 2000 and H 2001 IFD9502 is able to download maximum 8 words to AC motor drive The length of data uploaded to IFD9502 from AC motor drive is preset as 2 words at addres...

Страница 11: ...4 Get Set Data_in 3 UINT H FFFF 15 Get Set Data_in 4 UINT H FFFF 16 Get Set Data_in 5 UINT H FFFF 17 Get Set Data_in 6 UINT H FFFF 18 Get Set Data_In 7 UINT H FFFF 25 Get Set Data_out 0 UINT H 2101 26...

Страница 12: ...et the node address of PLC as 01 and the communication format as 115 200 bps 7 E 1 ASCII the format is fixed other formats will be invalid 2 Class 0x96 parameter z Instance0 Attribute ID Access rule N...

Страница 13: ...B Service data MSB z Explanation Position address refers to the No of the device in the register of PLC For example the position address of M0 is 0 and that of D100 is 100 Number refers to the number...

Страница 14: ...t address of I O data mapping Default length of I O data mapping Max Length of I O data mapping Unit Description D500 H 11F4 6 128 word DeviceNet PLC M512 H 0A00 10 256 bit M 8 D 2 Max size 256 bytes...

Страница 15: ...start_adr UINT H 0100 7 Get Set D_in_start_adr UINT H 0198 8 Get Set M_out_start_adr UINT H 0200 9 Get Set D_out_start_adr UINT H 01F4 10 Get Set Comm Timeout UINT H 0020 3 3 When IFD9502 is connected...

Страница 16: ...e code 0x0E 2 N A Response data LSB 3 N A Response data MSB 3 I O data mapping Default z Temperature controller DeviceNet master Node address of AC motor drive b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b...

Страница 17: ...n 2 UINT H FFFF 14 Get Set Data_in 3 UINT H FFFF 15 Get Set Data_in 4 UINT H FFFF 16 Get Set Data_in 5 UINT H FFFF 17 Get Set Data_in 6 UINT H FFFF 18 Get Set Data_in 7 UINT H FFFF 25 Get Set Data_out...

Страница 18: ...owing parameters before connecting the servo drive to IFD9502 y P3 00 H 0001 set node address to 1 y P3 01 H 0005 set baud rate to 115 200 bps y P3 02 H 0001 set communication format as ASCII 7 E 1 y...

Страница 19: ...b8 b7 b6 b5 b4 b3 b2 b1 b0 H 0407 Digital input DI1 DI8 z Explanation When the equipment connected to IFD9502 is a servo drive the length of data downloaded from IFD9502 to the servo drive is preset...

Страница 20: ...FFFF 23 Get Set Data_in 12 UINT H FFFF 24 Get Set Data_in 13 UINT H FFFF 25 Get Set Data_in 14 UINT H FFFF 26 Get Set Data_in 15 UINT H FFFF 31 Get Set Data_out 0 UINT H 0409 32 Get Set Data_out 1 UIN...

Страница 21: ...ing the Delta HMI to bus set the node address of HMI as 01 and the communication format as 115 200 7 E 1 ASCII the format is fixed other formats will be invalid z When IFD9502 is connected to Delta DO...

Страница 22: ...SCII Click OK z When IFD9502 is connected to TP04 TP02 please set up the baud rate and format following the procedure listed below Open TPEditor and select File New You will see the dialog box as belo...

Страница 23: ...IFD9502 Node address of IFD9502 b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 D32 DOP reads register of IFD9502 D33 DOP reads register of IFD9502 D34 DOP reads register of IFD9502 D35 DOP read...

Страница 24: ...ent In the custom mode IFD9502 can still establish EXP IO connection when there is no equipment connected to it 1 Settings of the equipment connected to IFD9502 in custom mode Before connecting the cu...

Страница 25: ...mmon Services Implemented for Service Code Class Instance Service Name 0x0E Yes Yes Get_Attribute_Single 0x10 No Yes Set_Attribute_Single z Explanation When you need to use DeviceNet Config software t...

Страница 26: ...tribute1 of Instance1 of Class 0x9F into H 0001 and re power IFD9502 Please note that doing so can only recover the current I O data mapping in the custom equipment Class 0x9F Custom Data Config Insta...

Страница 27: ...and re power IFD9502 In the custom mode if you are to return the I O mapping of servo drive to default setting change Attribute150 of Instance2 of Class 0x9F into H 0001 and re power IFD9502 In the cu...

Страница 28: ...network installation is normal 3 Check if the baud rate of IFD9502 is consistent with that of the BUS 4 Check if the station No of IFD9502 is valid 5 Check if your choice of switch on IFD9502 is consi...

Страница 29: ...re the communication cable meets the specification 5 DeviceNet Objects IFD9502 Supports This section provides details of the objects instances and attributes supported by IFD9502 in DeviceNet network...

Страница 30: ...10 Yes No Find_Next_Object_Instance 3 Class 0x02 Message router z Class attributes Attribute ID Access rule Name Data type 1 Get Revision UINT 6 Get MaxIdClass UINT 7 Get MaxIdInstance UINT z Instance...

Страница 31: ...No Yes Release_Master Slave_Connection_Set 5 Class 0x05 Connection z Class attributes Attribute ID Access rule Name Data type 1 Get Revision UINT z Instance 1 Master Slave Explicit Message Connection...

Страница 32: ...ced Connection Path EPATH 15 Get Consumed Connection Path Length USINT 16 Get Consumed Connection Path EPATH z Common Services Implemented for Service code Class Instance Service name 0x05 No Yes Rese...

Страница 33: ...Get Data Type USINT 6 Get Data Size USINT z Common Services Implemented for Service code Class Instance Service Name 0x0E Yes Yes Get_Attribute_Single 0x10 No Yes Set_Attribute_Single 8 Class 0x95 AM...

Страница 34: ...nstance Service name 0x05 Yes Yes Reset 0x0E Yes Yes Get_Attribute_Single 0x10 No Yes Set_Attribute_Single 9 Class 0x96 PLC_Access z Class attributes Attribute ID Access rule Name Data type 1 Get Revi...

Страница 35: ...H 0200 9 Get Set D_out_start_adr UINT H 01F4 10 Get Set Comm Timeout UINT H 0020 z Common Services Implemented for Service code Class Instance Service Name 0X05 Yes Yes Reset 0x0E Yes Yes Get_Attribut...

Страница 36: ..._out 1 UINT H 4719 27 Get Set data_out 2 UINT H FFFF 28 Get Set data_out 3 UINT H FFFF 29 Get Set data_out 4 UINT H FFFF 30 Get Set data_out 5 UINT H FFFF 31 Get Set data_out 6 UINT H FFFF 32 Get Set...

Страница 37: ...H FFFF 19 Get Set data_in 8 UINT H FFFF 20 Get Set data_in 9 UINT H FFFF 21 Get Set data_in 10 UINT H FFFF 22 Get Set data_in 11 UINT H FFFF 23 Get Set data_in 12 UINT H FFFF 24 Get Set data_in 13 UIN...

Страница 38: ...ibute ID Access rule Name Data type Default 1 Get set resetparameter UINT 66H 2 Get Set dlen_in USINT 4 3 Get Set dlen_out USINT 4 z Common Services Implemented for Service code Class Instance Service...

Страница 39: ...NT H FFFF z Instance 2 EEPROM read write Attribute ID decimal Access rule Name Data type 30 Get Set AMD reset parameter H 0066 71 Get Set PLC reset parameter H 0066 90 Get Set DTA reset parameter H 00...

Страница 40: ...ATA DATA 3 4 3 4 1 2 3 4 5 6 2 When IFD9502 is connected to Delta DVP series PLC By RS 485 communication IFD9502 RJ 12 RS 485 DVP PLC RS 485 wiring terminal DATA DATA DATA DATA 3 4 1 2 3 4 5 6 RJ 12 _...

Страница 41: ...D series AC motor drive By RS 485 communication IFD9502 DB9 female RS 485 VFD series AC motor drive RJ 11 RS 485 DATA DATA 3 8 DATA DATA 5 9 4 8 3 7 2 6 1 DB9 female RJ 12 1 2 3 4 5 6 3 4 2 When IFD95...

Страница 42: ...RS 232 communication IFD9502 DB9 female RS 232 ASDA CN3 connector RS 232 CN3 connector 1 3 5 2 4 6 5 9 4 8 3 7 2 6 1 DB9 female TX RX RXD TXD 2 3 GND 5 2 4 1 GND z By RS 485 communication IFD9502 DB9...

Страница 43: ...unication Module IFD9502 DVP PLC Application Manual 41 z By RS 485 communication IFD9502 DB9 female RS 485 DOP DB9 male RS 485 5 9 4 8 3 7 2 6 1 DOP COM2 5 9 4 8 3 7 2 6 1 DB9 female DATA DATA 8 3 2 4...

Отзывы: