196
Script Commands
3
Do not make any configuration changes to the storage array while
downloading the physical disk firmware. Attempting to make a
configuration change can cause the firmware download to fail and make
the selected physical disks unusable.
You can use this command to test the firmware on one physical disk before
installing the firmware on all of the physical disks in a storage array. (Use the
download storageArray physicalDiskFirmware
command to download
firmware on all of the physical disks in the storage array.) This command
blocks all I/O activity until the download finishes or fails. The download
returns one of the following statuses:
• Successful
• Unsuccessful With Reason
• Never Attempted With Reason.
Syntax
download physicalDisk [
enclosureID,slotID
]
firmware file="
filename
"
Parameters
Parameter
Description
physicalDisk
Physical disk to which to download the
firmware image. Specify the enclosure ID
and slot ID for the physical disk.
Enclosure ID values are 0 to 99. Slot ID
values are 0 to 31. You must put brackets
([ ]) around the enclosure ID value and
slot ID value.
filename
File path and file name of the file that
contains the firmware image. You must
put quotation marks (" ") around the
firmware image file path and file name.
book.book Page 196 Wednesday, June 8, 2011 12:20 PM
Содержание PowerVault MD3600f Series
Страница 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Страница 44: ...44 About the Script Commands ...
Страница 114: ...114 Using the Remote Replication Premium Feature ...
Страница 311: ...Script Commands 311 ...
Страница 312: ...312 Script Commands ...
Страница 318: ...318 Sample Script Files ...
Страница 328: ...Index 328 ...