Script Commands
265
modificationPriority
The priority for virtual disk modifications
while the storage array is operational. Valid
values are
highest
,
high
,
medium
,
low
, or
lowest
.
owner
The RAID controller module that owns the
virtual disk. Valid RAID controller module
identifiers are 0 or 1, where, 0 is the RAID
controller module in slot 0, and 1 is the RAID
controller module in slot 1. Use this parameter
only if you want to change the virtual disk
owner.
readCacheEnabled
The setting to turn on or turn off the read
cache. To turn on the read cache, set this
parameter to
TRUE
. To turn off the read
cache, set this parameter to
FALSE
.
writeCacheEnabled
The setting to turn on or turn off the write
cache. To turn on the write cache, set this
parameter to
TRUE
. To turn off the write
cache, set this parameter to
FALSE
.
cacheReadPrefetch
The setting to turn on or turn off cache read
prefetch. To turn off cache read prefetch, set
this parameter to
FALSE
. To turn on cache
read prefetch, set this parameter to
TRUE
.
addCapacity
The setting to increase the storage size
(capacity) of the virtual disk for which you are
defining properties. Size is defined in units of
bytes,
KB
,
MB
,
GB
, or
TB
. The default value
is
bytes
.
NOTE:
A space must be added between the last
digit and the size (bytes, KB, MB, or GB) for
values greater than 9.
Parameter
Description
book.book Page 265 Wednesday, June 8, 2011 12:20 PM
Содержание PowerVault MD3600f Series
Страница 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Страница 44: ...44 About the Script Commands ...
Страница 114: ...114 Using the Remote Replication Premium Feature ...
Страница 311: ...Script Commands 311 ...
Страница 312: ...312 Script Commands ...
Страница 318: ...318 Sample Script Files ...
Страница 328: ...Index 328 ...