260
Script Commands
Set Storage Array Redundancy Mode
This command sets the redundancy mode of the storage array to either
simplex or duplex.
Syntax
set storageArray redundancyMode=(simplex | duplex)
Parameter
Set Storage Array Security Key
Use this command to set the security key that is used throughout the storage
array to implement the Physical Disk Security premium feature. When any
security-capable physical disk in the storage array is assigned to a secured disk
group, that physical disk is security-enabled using the security key. Before you
can set the security key, you must use the
create storageArray securityKe
y
command to create the security key.
Syntax
set storageArray securityKey
Parameters
None.
Additional Information
Security-capable physical disks have hardware to accelerate cryptographic
processing and each has a unique physical disk key. A security-capable
physical disk behaves like any other physical disk until it is added to a secured
disk group. When a security-capable physical disk is added to a secured disk
group, it becomes security-enabled.
Parameter
Description
redundancyMode
Use
simplex
mode when you have a single RAID
controller module. Use
duplex
mode when you have two
RAID controller modules
book.book Page 260 Wednesday, June 8, 2011 12:20 PM
Содержание PowerVault MD3600f Series
Страница 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Страница 44: ...44 About the Script Commands ...
Страница 114: ...114 Using the Remote Replication Premium Feature ...
Страница 311: ...Script Commands 311 ...
Страница 312: ...312 Script Commands ...
Страница 318: ...318 Sample Script Files ...
Страница 328: ...Index 328 ...