PowerConnect B-FCX Switch Hardware Installation Guide
13
53-1002267-01
Hardware features
1
FIGURE 15
Power status LEDs
NOTE
Both “AC OK” and “DC OK” LEDs must be green for the device to function normally.
Power supplies
The device has two power receptacles on the rear panel. Each device ships with one power supply
installed. PowerConnect B-FCX624s, PowerConnect B-FCX648s, PowerConnect B-FCX624, and
PowerConnect B-FCX648 devices use a 210W PSU.
1
Power status LEDs
TABLE 13
Power status LEDs
LED
Condition
Status
DC OK
Green
DC output ok
Red DC
output
fail
AC OK
Green
AC input ok
Off
AC input fail
TABLE 14
Switch status for two installed power supply units
State
LED
PSU1
PSU2
Switch Status
Redundancy
Four Green PSU
LEDs
AC OK
Green
Green
Running
Yes
DC OK
Green
Green
Single Red ‘DC
OK’ LED
AC OK
Green
Green
Running
No
DC OK
Green
Red
Both ‘DC OK’
LEDs Red
AC OK
Green
Green
Failure
No
DC OK
Red
Red
One PSU with
both ‘AC OK’ ‘DC
OK’ LEDs Off
AC OK
Green
Off
Running
No
DC OK
Green
Off
‘DC OK’ LEDs Red
and Off
AC OK
Green
Off
Failure
No
DC OK
Red
Off
All ‘AC OK’ LEDs
Off
AC OK
Off
Off
Power Off or
Failure
No
DC OK
Off
Off
1
Содержание PowerConnect B-FCX
Страница 1: ...53 1002267 01 18 March 2011 PowerConnect B FCX Switch Hardware Installation Guide ...
Страница 6: ...vi PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 ...
Страница 10: ...x PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 ...
Страница 58: ...48 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Troubleshooting network connections 3 ...
Страница 74: ...64 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Hardware specifications 5 ...
Страница 80: ...70 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Regulatory compliance A ...
Страница 86: ...76 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Danger notices B ...