NOTE:
Ensure that the processor and heat sink is held parallel to the system board to prevent damaging the
components.
Figure 60. Installing the processor and heat sink (PHM)
3. Set the Anti-Tilt wires to the locked position (outward position), and then using the Torx #T30 screwdriver, tighten the
screws (8 in-lbf) on the heat sink in the order below:
a. Tighten the first screw three turns.
b. Tighten the screw diagonally opposite to the screw you tighten first.
c. Repeat the procedure for the remaining two screws.
d. Return to the first screw to tighten it completely.