Table 16. DD9500 with ES30 DD Cloud Tier or HA and DD Cloud Tier primary node cabling
instructions (continued)
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 2 - Port 0
A controller HOST
port of the highest number shelf in V1
3M
2
I/O 3 - Port 0
B controller HOST
port of shelf V2.1
2M
2
I/O 9 - Port 1
A controller HOST
port of the highest number shelf in V2
2M
3
I/O 2 - Port 1
B controller HOST
port of shelf V3.1
2M
3
I/O 6 - Port 0
A controller HOST
port of the highest number shelf in V3
2M
4
I/O 3 - Port 3
B controller HOST
port of shelf V4.1
3M
4
I/O 2 - Port 2
A controller HOST
port of the highest number shelf in V4
3M
5
I/O 3 - Port 2
B controller HOST
port of shelf V5.1
3M
5
I/O 9 - Port 2
A controller HOST
port of the highest number shelf in V5
3M
6
I/O 2 - Port 3
B controller HOST
port of shelf V6.1
3M
6
I/O 6 - Port 3
A controller HOST
port of the highest number shelf in V6
3M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
Table 17. DD9500 with ES30 DD Cloud Tier or HA and DD Cloud Tier standby node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 3 - Port 1
A controller EXPANSION
port of shelf V1.1
2M
1
I/O 2 - Port 0
B controller EXPANSION
port of the highest number shelf in V1
3M
2
I/O 3 - Port 0
A controller EXPANSION
port of shelf V2.1
2M
2
I/O 9 - Port 1
B controller EXPANSION
port of the highest number shelf in V2
2M
3
I/O 2 - Port 1
A controller EXPANSION
port of shelf V3.1
2M
3
I/O 6 - Port 0
B controller EXPANSION
port of the highest number shelf in V3
2M
4
I/O 3 - Port 3
A controller EXPANSION
port of shelf V4.1
3M
4
I/O 2 - Port 2
B controller EXPANSION
port of the highest number shelf in V4
3M
5
I/O 3 - Port 2
A controller EXPANSION
port of shelf V5.1
3M
5
I/O 9 - Port 2
B controller EXPANSION
port of the highest number shelf in V5
3M
6
I/O 2 - Port 3
A controller EXPANSION
port of shelf V6.1
3M
6
I/O 6 - Port 3
B controller EXPANSION
port of the highest number shelf in V6
3M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
62
Connect Cables and Power On
Содержание Data Domain DD9500
Страница 1: ...Dell EMC Data Domain DD9500 System Installation and Storage Expansion Guide November 2021 Rev 02 ...
Страница 65: ...Figure 66 DD9500 with ES30 shelves ERSO Connect Cables and Power On 65 ...
Страница 68: ...Figure 68 DD9500 with DS60 shelves DD9500 with HA For an HA DD9500 pair 68 Connect Cables and Power On ...