Table 4 Truss head screws
Truss head screw from kit
Part number and
description
Suggested use
036-032-010
Screw, M5-0.8x12, Truss
Head Phillips with patch
Can be used in Dell EMC
racks and third-party non-
threaded hole racks.
036-032-011
Screw, M6-1.0x12, Truss
Head Phillips with patch
Can be used in non-Dell EMC
racks.
036-032-009
Screw, 10-32x.5, Truss Head
Phillips with patch
Can be used in non-Dell EMC
racks.
036-032-012
Screw, 12-24x.5, Truss Head
Phillips with patch
Can be used in non-Dell EMC
racks.
Procedure
1. For Dell EMC racks, use the orange shelf latch handles to push the shelf completely into the
cabinet. Align the two semi-captive M5 shoulder screws on each side with the mounting
holes on the cabinet. Thread the shoulder screws into the mounting holes and finger-tighten
the shoulder screws.
Figure 27 Inserting and securing the shelf to the cabinet (shoulder screw configuration)
l
To install the shelf into a third-party rack that is not compatible with the M5 shoulder
screws, do the following:
Install the Disk Shelves in the Rack
Dell EMC PowerProtect DD9900 System Installation Guide
41
Содержание PowerProtect DD9900
Страница 1: ...Dell EMC PowerProtect DD9900 System Installation Guide Revision 01 September 2019...
Страница 8: ...Tables 8 Dell EMC PowerProtect DD9900 System Installation Guide...
Страница 18: ...Introduction and Preparation 18 Dell EMC PowerProtect DD9900 System Installation Guide...
Страница 32: ...Install the System in the Rack 32 Dell EMC PowerProtect DD9900 System Installation Guide...
Страница 70: ...Connect Cables and Power On 70 Dell EMC PowerProtect DD9900 System Installation Guide...
Страница 96: ...Configure System for Use 96 Dell EMC PowerProtect DD9900 System Installation Guide...