Error Code
Message Information
Details
The chassis is open. System performance may be degraded, and security may be
compromised.
Action
Close the chassis. Check system logs.
SEC0033
Message
The chassis is open while the power is off.
LCD Message
Intrusion detected. Check chassis cover.
Details
The chassis was opened while the power was off. System security may have been
compromised.
Action
Close the chassis and verify hardware inventory. Check system logs.
SEL0006
Message
All event logging is disabled.
Details
This message is displayed when all event logging has been disabled by the user.
Action
If unintended, re-enable logging.
SEL0008
Message
Log is full.
Details
When the event log is full, additional events are not written to the log. Older events may
be overwritten and lost. This message may also appear if the user disabled event logging.
Action
Backup and clear log.
SEL0012
Message
Could not create or initialize the system event log.
Details
If the system event log fails to initialize, platform status and failure events are not
captured. Some management software do not report platform exceptions.
Action
Reboot the management controller or iDRAC. Cycle system input power. If problem
persists call support.
SEL1204
Message
An unknown system hardware failure detected.
LCD Message
Unknown system hardware failure.
Details
If the system event log failed to initialize, platform status and failure events are not
captured. Some management software do not report platform exceptions.
Action
Re-configure system to the minimum supported configuration. If issues persists, contact
support.
TMP0118
Message
The system inlet temperature is less than the lower warning threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0119
Message
The system inlet temperature is less than the lower critical threshold.
LCD Message
System inlet temperature is outside of range.
128
System messages