Error Code
Message Information
Details
The operating system or an application failed to communicate within the time-out
period. The system was power-cycled.
Action
Check the operating system, application, hardware, and system event log for exception
events.
BAT0002
Message
The system board battery has failed.
LCD Message
The system board battery has failed. Check battery.
Details
The system board battery is either missing or bad.
Action
BAT0017
Message
The <
name
> battery has failed.
LCD Message
The <
name
> battery has failed. Check battery.
Details
The <
name
> battery is either missing, bad, or unable to charge due to thermal issues.
Action
Check system fans. If the problem persists, see
.
CPU0000
Message
CPU <
number
> has an internal error (IERR).
LCD Message
CPU <
number
> has an internal error (IERR).
Details
System Event Log and Operating System Logs may indicate that the exception is external
to the processor.
Action
Review System Event Log and Operating System Logs. If the issue persists, see
CPU0001
Message
CPU <
number
> has a thermal trip (over-temperature) event.
LCD Message
CPU <
number
> has a thermal trip. Check CPU heat sink.
Details
The processor temperature increased beyond the operational range.
Action
Review the logs for fan failures. If no fan failures are detected, check inlet temperature (if
available) and reinstall processor heat sink. If the problem persists, see
.
CPU0005
Message
CPU <
number
> configuration is unsupported.
LCD Message
CPU <
number
> configuration is unsupported. Check CPU or BIOS revision.
Details
System is unable to boot or may run in a degraded state.
Action
Review the technical specifications for supported processor types.
CPU0010
Message
CPU <
number
> is throttled.
Details
The CPU is throttled due to thermal or power conditions.
Action
Review system logs for power or thermal exceptions.
CPU0023
Message
CPU <
number
> is absent.
118