CURRENT COUNT - (display only) the total number counted since the last reset. The
maximum display value is 9999. It cannot be adjusted, except with the Reset key (next
section), which forces the value to zero.
TARGET COUNT - (adjustable set point) the desired number per container. The
maximum value is 9999.
SLOWDOWN COUNT - (adjustable) the number of items to be counted to cause the
disc to slow down as the Target Count is approached. The maximum value is 9999. The
value must be less than the Target Count.
NOTE: The Target Count must be set to a value greater than the
Slowdown Count or the counter will not automatically reset when the
Target Count is reached,
FLAG DELAY - (adjustable) a time delay between the moment the Target Count is
reached and when the flag flips. This is to allow enough time for the target count pill to
fall from the counting window to the divider flag. The maximum set point value is 0.99
sec. Generally, the usable range is 0.0 to 0.05 sec.
7.1.2.
ACTION KEYS
The four click-membrane keys are marked AUTO, MANUAL, CHECK COUNT and
RESET.
AUTO – This is the production-filling mode. Press AUTO to start the disc (and feeder, if
equipped) to begin delivering product. The machine will now continuously count
product, alternately discharging to the right or left funnel. Containers must be
continuously supplied and removed in sync with the machine. Press AUTO again to stop,
or press the RED E-STOP BUTTON on the right side.
MANUAL – This used to fill one container at a time manually. Press to start the disc
(and feeder, if equipped) to begin delivering product until the target count is reached one
time. Product delivery will stop, the flag will flip and the counter will reset. After the
reset, any product that runs on is counted and discharged to the alternate funnel. Press
again to repeat. Good for parameter testing, check counting and casual production filling.
CHECK COUNT – This mode will count continuously without flipping the divider flag.
The Target Count and Slowdown Count are ignored. Press to begin delivering product
and counting. Counting will continue until you press the button again. In Check Count
mode, the maximum count is 99,999,999, although the display will only show the last
four numerals.
Содержание PHARMAFILL TC4
Страница 1: ...Model TC4 Electronic Counter Operation Manual...
Страница 52: ......
Страница 53: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......