Rev 2022-03-08
Pharmafill Model TC4 User Manual
Deitz Company Inc.
TC4 User Manual
Page
17
7.4.
PRODUCT GUIDE ADJUSTMENTS
The guide adjustments create a steady flow of product down the channel, into the chute and
through the center of the counting window. The flow must be single file, one level high.
7.4.1.
WIDTH – The channel width is adjusted by moving the Guide Block Assembly side-
to-side. To adjust, loosen the knob and move the guide block to the left. Place a few
pills in the channel and move the guide to the right so that only a single file row may
pass down the channel. Leave enough room so that the product will flow freely. Tighten
the knob. NOTE: if the guide block will not open fully, check that the Guide Plate depth
is not limiting the travel.
7.4.2.
DEPTH – The Guide Plate is kept close to the edge of the glass disc by the depth
(front-to-back) after the width is set. Loosen the two knobs on the Guide Plate just
enough to move the plate. Slide it forward until it touches the edge of the glass disc, and
then move it back a bit so that it does not drag on the disc (adjust for minimum
clearance). As you tighten the two knobs, rotate the Guide Plate forward so that the
pointed tip of the Flow Diverter is lightly touching the glass disc.
KNOB
GU
IDE BLOCK ASS’Y
FLOW DIVERTER
(LONG, POINTED)
GUIDE PLATE
Содержание PHARMAFILL TC4
Страница 1: ...Model TC4 Electronic Counter Operation Manual...
Страница 52: ......
Страница 53: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......