Rev 2022-03-08
Pharmafill Model TC4 User Manual
Deitz Company Inc.
TC4 User Manual
Page
39
h.
Auxiliary outlet has no power.
❑
Check component fuse F3 (outlet) inside behind right side access panel (LED
“on” indicates blown fuse).
i.
Divider Flag does not flip (does not switch sides alternately)
❑
Power down and check that the flag moves freely back and forth.
❑
Check the electrical connections to the left and right actuator solenoids.
❑
Check that the red output lights Y4 and Y5 on the PLC turn on alternately for left
and right.
j.
Count is not accurate – too many in container (sensor missing pills)
❑
Check that the counting head is centered on the exit chute.
❑
Check that the bar graph indicator lights on the counting sensor are dropping and
rising as objects pass through the sensor.
❑
Check that the product flow is consistently single file, one level high (no doubles
or piggy backs)
❑
Contact Deitz Company for more detailed troubleshooting help.
k.
Count is not accurate – too few in container
❑
In the case of clear or translucent product, check the adjustment the one-shot
delay.
❑
Check that small chips are not being counted as whole
❑
In the case of long or irregularly-shaped product, make sure that he product is not
tumbling through the counting window and occasionally being counting twice.
❑
Contact Deitz Company for more detailed troubleshooting help.
l.
Count is not accurate – random
❑
Contact Deitz Company for more detailed troubleshooting help.
Содержание PHARMAFILL TC4
Страница 1: ...Model TC4 Electronic Counter Operation Manual...
Страница 52: ......
Страница 53: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......