background image

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

1

z

LCD, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE

WITH YELLOW/GREEN OR RED LED BACKLIGHTING 

z

INTERNAL LITHIUM BATTERY PROVIDES UP TO 6 YEARS OF

UNINTERRUPTED OPERATION

z

NEMA 4X/IP65 SEALED FRONT BEZEL

z

FRONT PANEL RESET, REMOTE RESET, OR BOTH

z

COUNT SPEEDS UP TO 5 KHz (Model Dependent)

z

COUNT INPUT FROM 10 to 300 VAC/DC (CUB4L8W)

z

WIRE CONNECTION MADE VIA SCREW CLAMP TYPE

TERMINALS

DESCRIPTION

The CUB4 offers a large display in a miniature package. There are three

CUB4 counters to choose from; the CUB4L (6-digit counter), CUB4L8 (8-digit
counter), and the CUB4L8W (8-digit counter with voltage input). You also have
a choice of three displays; reflective, red backlight or green backlight.

The backlight versions require power from an external 9–28 VDC supply. The

optional power supply (MLPS1000) is designed to be attached directly to the rear
of the CUB4 and is powered from an 85–250 VAC source. The power supply
provides 12 VDC @ 400 mA to power the backlight and sensor, if required.

The CUB4 series has a lightweight, high impact plastic case with a clear

viewing window. The sealed front panel with the silicone rubber reset button
meets NEMA 4X/IP65 specifications for wash-down and/or dusty
environments, when properly installed.

ORDERING INFORMATION

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

SPECIFICATIONS

1. 

DISPLAY

CUB4L: 6-Digit, LCD, 0.48" 

(12.2 mm)

high digits. 

CUB4L8 & CUB4L8W: 8-Digit, LCD, 0.46" 

(11.7 mm)

high digits. 

2. 

POWER SOURCE

: Internal 3.0 V lithium battery to provide up to 6 years

of continuous operation. Battery life is dependent upon usage. Count and reset
contacts that remain closed for long periods of time will reduce battery life. 

3. 

BACKLIGHT POWER REQUIREMENTS

: 9 to 28 VDC, 35 mA typical,

50 mA max. Above 26 VDC, derate operating temperature to 50°C. 
Must use the MLPS or a Class 2 or SELV rated power supply.

4. 

INPUTS

All Inputs

: V

IL

(low)

= 0.5 V max.

Low Speed Input (CUB4L & CUB4L8)

: 30 Hz from switch contact or open

collector transistor with a 50% duty cycle.

Low Speed Input (CUB4L8W)

: 10 to 300 VAC/DC, 50/60 Hz, 30 cps max.

V

IL

= 0.5 VDC max. Unit counts on positive going edge. Will not operate

with Triac outputs.

High Speed Input (CUB4L)

: 5 KHz from 4.0 V to 28.0 V bipolar output

with a 50% duty cycle.

High Speed Input (CUB4L8)

: 5 KHz at 2.0 V (3 V max) bipolar output with

a 50% duty cycle.

Remote Reset

:

CUB4L: 15 msec min. pulse width 

(active low)

from 4.0 V to 28.0 V bipolar

output or an open collector transistor or a switch contact to common. 

MODEL CUB4L, CUB4L8 & CUB4L8W - MINIATURE ELECTRONIC COUNTERS

DIMENSIONS   In inches (mm)

CAUTION: Risk of Danger.

Read complete instructions prior to
installation and operation of the unit.

UL Recognized Component,
File # E179259

Bulletin No.  CUB4-B
Drawing No.  LP0585
Released  3/07

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Note: Recommended minimum clearance (behind the panel) for mounting clip

installation is 2.15" (54.6) H x 3.00" (76.2) W.

PANEL CUT-OUT

MLPS1000

Micro Line/Sensor Power Supply

MLPS

Counter Positive Image Reflective w/V+ Terminal

Counter Positive Image Reflective w/V+ Terminal

Counter Positive Image Reflective w/V+ Terminal

CUB4LM00

CUB4L80M

CUB4L8WM

CUB4L020

CUB4L820

CUB4L8W2

Counter w/Red Backlighting

Counter w/Red Backlighting

Counter w/Red Backlighting

CUB4L

(6-digit)

CUB4L8

(8-digit)

CUB4L8W

(8-digit 

w/VCM)

CUB4L010

CUB4L810

CUB4L8W1

Counter w/Yel-Grn Backlighting

Counter w/Yel-Grn Backlighting

Counter w/Yel-Grn Backlighting

For more information on Pricing, Enclosures & Panel Mount Kits refer to the RLC
Catalog or contact your local RLC distributor.

CUB4L000

CUB4L800

CUB4L8W0

Counter Positive Image Reflective

Counter Positive Image Reflective

Counter Positive Image Reflective

PART NUMBERS

DESCRIPTION

MODEL NO.

Содержание CUB4L

Страница 1: ...tery life is dependent upon usage Count and reset contacts that remain closed for long periods of time will reduce battery life 3 BACKLIGHT POWER REQUIREMENTS 9 to 28 VDC 35 mA typical 50 mA max Above 26 VDC derate operating temperature to 50 C Must use the MLPS or a Class 2 or SELV rated power supply 4 INPUTS All Inputs VIL low 0 5 V max Low Speed Input CUB4L CUB4L8 30 Hz from switch contact or o...

Страница 2: ... rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY Refer to the EMC Installation Guidelines section of this bulletin for additional information 7 CONSTRUCTION This unit is rated for NEMA 4X IP65 indoor use Installation Category I Pollution Degree 2 8 WEIGHT 3 oz 85 grams EMC INSTALLATION GUIDELINES Although Red Lion Controls Products are designed with a high degree of immunity to Electromagne...

Страница 3: ...ew until the wire is clamped tightly Each terminal can accept up to two 14 AWG wires Note The Reflective CUB4 will NOT have a screw terminal installed at the V terminal since it is NOT required for operation and is not internally connected Refer to the Ordering Information for the part number of a reflective model that will accommodate the MLPS Backlight Wiring Optional backlight versions of the C...

Страница 4: ...lighting and a sensor WARNING When connecting the wiring for a backlit CUB4L8W measuring an AC input voltage the neutral of the single phase AC signal is connected to Terminal 1 COM and line hot is connected to Terminal 5 LS The DC supply for the backlighting is connected as shown in the drawing Three phase AC applications require an isolation transformer The H S CNT Input allows the CUB Counter t...

Отзывы: