background image

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

3

CUB4L AND CUB4L8 LOW SPEED COUNT INPUT, 30 Hz MAX.

Pulling the “L.S. CNT.” Input to Common

with a mechanical or solid-state switch
increments the counter. The low pass filter used
with a Schmidt trigger circuit debounces
mechanical switch signals. The switch load is
14 µA (max. voltage drop 0.5 V) when ON. The
OFF-state leakage current must be less than 2
µA. Motor starter contacts, tungsten contacts,
and brush-type contacts should NOT be used.

WIRING CONNECTIONS

The electrical connections are made via rear screw-clamp terminals located

on the back of the unit. When wiring the unit, use the label to identify the wire
position with the proper function. All conductors should meet voltage and
current ratings for each terminal. Also cabling should conform to appropriate
standards of good installation, local codes and regulations. It is recommended
that power supplied to the unit (AC or DC) be protected by a fuse or circuit
breaker. Strip the wire, leaving approximately 1/4" bare wire exposed 

(stranded

wires should be tinned with solder)

. Insert the wire into the screw-clamp

terminal and tighten down the screw until the wire is clamped tightly. Each
terminal can accept up to two #14 AWG wires. 

Note: The Reflective CUB4 will 

NOT

have a screw terminal installed at the V+

terminal, since it is 

NOT

required for operation and is not internally

connected. Refer to the Ordering Information for the part number of a
reflective model that will accommodate the MLPS.

Backlight Wiring

Optional backlight versions of the CUB4 require an external 9-28 VDC

power supply. The external supply is connected between the V+ and Common
terminals.

Warning:

Lithium battery may explode if incinerated.

Caution

: All leads will be at the same line potential as the input leads.

CUB4L8W L.S. INPUT, 30 CPS MAX.

The CUB4L8W accepts most machine control voltage signals. The input

accepts AC (50/60 Hz) or DC control voltages from 10 to 300 V at count speeds
up to 30 cps. The unit counts on the positive going edge of the input signal.

WARNING

: Any lead may be at hazardous live input potential.

External wiring and devices connected to the unit must be rated
the same as applied signal input voltage and be properly
isolated from Class 2 or SELV circuitry.

CUB4L HIGH SPEED COUNT INPUT, 5 KHz MAX.

The 

“H.S. CNT.”

Input allows the CUB

Counter to operate at speeds up to 5 KHz
when driven by bi-polar outputs. Input drive
voltage must be limited to 28.0 V maximum
to avoid damage to the counter.

INPUT PULSE EXCURSION LIMITS

V

IH

(High) = +4.0 V min.,  +28.0 V max.

V

IL

(Low) = +0.5 V max.

Содержание CUB4L

Страница 1: ...tery life is dependent upon usage Count and reset contacts that remain closed for long periods of time will reduce battery life 3 BACKLIGHT POWER REQUIREMENTS 9 to 28 VDC 35 mA typical 50 mA max Above 26 VDC derate operating temperature to 50 C Must use the MLPS or a Class 2 or SELV rated power supply 4 INPUTS All Inputs VIL low 0 5 V max Low Speed Input CUB4L CUB4L8 30 Hz from switch contact or o...

Страница 2: ... rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY Refer to the EMC Installation Guidelines section of this bulletin for additional information 7 CONSTRUCTION This unit is rated for NEMA 4X IP65 indoor use Installation Category I Pollution Degree 2 8 WEIGHT 3 oz 85 grams EMC INSTALLATION GUIDELINES Although Red Lion Controls Products are designed with a high degree of immunity to Electromagne...

Страница 3: ...ew until the wire is clamped tightly Each terminal can accept up to two 14 AWG wires Note The Reflective CUB4 will NOT have a screw terminal installed at the V terminal since it is NOT required for operation and is not internally connected Refer to the Ordering Information for the part number of a reflective model that will accommodate the MLPS Backlight Wiring Optional backlight versions of the C...

Страница 4: ...lighting and a sensor WARNING When connecting the wiring for a backlit CUB4L8W measuring an AC input voltage the neutral of the single phase AC signal is connected to Terminal 1 COM and line hot is connected to Terminal 5 LS The DC supply for the backlighting is connected as shown in the drawing Three phase AC applications require an isolation transformer The H S CNT Input allows the CUB Counter t...

Отзывы: