Rev 2022-03-08
Pharmafill Model TC3 User Manual
Deitz Company Inc.
TC3 User Manual
Page 27
7.11 - Counting Sensor
OVERVIEW
❑
Detects solid (opaque) product and translucent or clear product, such as gel caps.
❑
Automatically and continuously adjusts light level for maximum sensitivity
❑
Compensates for dust buildup and sets alarm if conditions become marginal.
Threshold Adjustment – how much the light level must drop to count.
When the light in the counting window is unblocked, the sensor detects 100% of the light.
When an object falls through the window, the light is blocked. If the threshold size is set to
40%, the sensor will send a count signal when 40% of the light is blocked; that is, when the
light level falls below 60%. The sensor will reset when the light level rises above 60% again.
This is the factory setting and works with most products. The threshold can be reduced to as
low as 5%.
Adjustable in 5% increments
Light bar 1=5%
Light bar 8 = 40% (factory setting, most products)
•
THRESHOLD FACTORY SETTING = 8 (good for all but the smallest pills)
One-Shot Delay Adjustment – how long the count signal stays on.
This is a feature for CLEAR PRODUCT ONLY. It is used to stretch the count signal so a
product with a clear center does not produce a “double” count. Normally set at the minimum
(5 ms) for solid product. For clear or opaque product, increase the one-shot according to the
length of the product. For example, 10 ms for round gel caps .25” long, or 40 ms for oblong
gel caps .90” long.
Adjustable in 5 millisecond increments
Light bar 1 = 5 ms (factory setting, for solid product)
Light bar 8 = 40 ms (for long clear products)
•
ONE-SHOT DELAY FACTORY SETTING = 1 (good for all solid product)
•
ONE-SHOT DELAY 2-8 is for CLEAR PRODUCTS ONLY
•
With ANY product, if the ONE-SHOT DELAY is set too high, it will cause
OVERFILLS (too many pills in the bottle)
•
With CLEAR product, if the ONE-SHOT DELAY is set too low, it will cause
UNDERFILLS (too few pills in the bottle).
Содержание Pharmafill TC3
Страница 1: ...Model TC3 Electronic Counter Operation Manual...
Страница 44: ...Rev 2022 03 08 Pharmafill Model TC3 User Manual Deitz Company Inc TC3 User Manual Page 32...
Страница 69: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......
Страница 84: ......