background image

82

new:
DIN 48 SIZE
LCD ELECTRONIC COUNTER
Scale factor, power supply

LC4H-S

NEW FEATURES:

1. Scale Factor:

A scale factor can be entered into LC4H-SV
series. After that one count shows the real
unit/value of the machine/application.

2. 12 V DC Power Supply:

The 100 – 240 V AC types are equipped 

with a 12 V DC power supply 100 mA. 
It is possible to connect photo-sensors,
proximity switches or encoders without addi-
tional devices.

3. Voltage Signal Input:

PNP input types are available.

FEATURES

1. Bright and Easy-to-Read Display

A brand new bright 2-color backlight LCD
display. The easy-to-read screen in any
location makes checking and setting pro-
cedures a cinch.

2. Simple Operation

Seesaw buttons make operating the unit
even easier than before.

3. Conforms to IP66’s Weather
Resistant Standards

The water-proof panel keeps out water
and dirt for reliable operation even in
poor environments.

4. Screw terminal and Pin Type are
Both Standard Options

The two terminal types are standard
options to support either front panel
installation or embedded installation.

5. 4-digit or 6-digit display

Two sizes of displays are offered for you
to choose the one that suits your needs.

6. Conforms With EMC and Low
Voltage Directives

Conforms with EMC directives
(EN50081-2/EN50082-2) and low-volt-
age directives (VDE0435/Part 2021) for
CE certification vital for use in Europe.

R4 / T4 systems (4-digit display)

R6 / T6 systems (6-digit display)

Pin type

Screw terminal type

PRODUCT TYPES

LC4H-SV

* A rubber gasket (ATC18002) and a mounting frame (AT8-DA4) are included.

mm 

inch

Digit

Count speed

Output

Operation voltage

Power down

Additional function

Terminal

P/N

insurane

Scale Factor

11 Pin

LC4H-PS-R4-AC240V

100-240 V AC

Scale Factor

Screw

LC4H-PS-R4-AC240VS

with 12V DC power supply

Scale Factor / Voltage Signal Input

11 Pin

LC4H-PSV-R4-AC240V

Relay

Scale Factor / Voltage Signal Input

Screw

LC4H-PSV-R4-AC240VS

Scale Factor

11 Pin

LC4H-S-R4-24V

4

Scale Factor

Screw

LC4H-S-R4-24VS

Scale Factor / Voltage Signal Input

11 Pin

LC4H-SV-R4-24V

12-24 V DC / 24 V AC

Scale Factor / Voltage Signal Input

Screw

LC4H-SV-R4-24VS

Scale Factor

11 Pin

LC4H-S-T4-24V

Transistor

Scale Factor

Screw

LC4H-S-T4-24VS

30 Hz (cps)

Scale Factor / Voltage Signal Input

11 Pin

LC4H-SV-T4-24V

5 kHz (kcps)

Available

Scale Factor / Voltage Signal Input

Screw

LC4H-SV-T4-24VS

switchable

Scale Factor

11 Pin

LC4H-PS-R6-AC240V

100-240 V AC

Scale Factor

Screw

LC4H-PS-R6-AC240VS

with 12V DC power supply

Scale Factor / Voltage Signal Input

11 Pin

LC4H-PSV-R6-AC240V

Relay

Scale Factor / Voltage Signal Input

Screw

LC4H-PSV-R6-AC240VS

Scale Factor

11 Pin

LC4H-S-R6-24V

Scale Factor

Screw

LC4H-S-R6-24VS

6

Scale Factor / Voltage Signal Input

11 Pin

LC4H-SV-R6-24V

12-24 V DC / 24 V AC

Scale Factor / Voltage Signal Input

Screw

LC4H-SV-R6-24VS

Scale Factor

11 Pin

LC4H-S-T6-24V

Transistor

Scale Factor

Screw

LC4H-S-T6-24VS

Scale Factor / Voltage Signal Input

11 Pin

LC4H-SV-T6-24V

Scale Factor / Voltage Signal Input

Screw

LC4H-SV-T6-24VS

48

1.890

48

1.890

64.5

2.539

02/2003

Содержание LC4H-S

Страница 1: ...tems 6 digit display Pin type Screw terminal type PRODUCT TYPES LC4H SV A rubber gasket ATC18002 and a mounting frame AT8 DA4 are included mm inch Digit Count speed Output Operation voltage Power down Additional function Terminal P N insurane Scale Factor 11 Pin LC4H PS R4 AC240V 100 240 V AC Scale Factor Screw LC4H PS R4 AC240VS with 12V DC power supply Scale Factor Voltage Signal Input 11 Pin LC...

Страница 2: ...en collector 1 0 107 ope At rated control voltage 12 to 24 V DC 24 V AC Max 3 W 100 mA 30 V DC Transistor output type DC AC type Rating Contact Life Electrical Mechanical Operating conditions Rated operating voltage Rated frequency Rated power consumption Rated control capacity Input mode Max counting speed Counting input input 1 input 2 Reset input Lock input Input signal Output mode One shot out...

Страница 3: ...ts are attached in a continuous series the dimension of A is Device installation rail ATA48011 sold separately Min 80 3 150 Min 80 3 150 95 5 112 9 3 760 4 445 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 A 48 n 2 5 0 6 0 With power supply for sensor NO NC 3 5 4 2 1 11 10 9 8 7 6 3 5 4 2 1 11 10 9 8 7 6 NO NC 3 5 4 2 1 11 10 9 8 7 6 0 V DC 12V 100mA Max 3 5 4 2 1 11 10 9 8 7 6 0 ...

Страница 4: ...tor T Lock indicator Y UP keys Changes the corresponding digit of the set value in the addition direction upwards U DOWN keys Changes the corresponding digit of the set value in the subtraction direction down wards I RESET switch Resets the counting value and the output O SET LOCK switch This is used to handle pre scaling values one shot times decimal point position set tings and key lock operatio...

Страница 5: ...dent and phase inputs The counting value is counted up or down to any number other than 0 once When it comes to 0 zero again the counter starts counting up E The decimal point is set using the UP and DOWN keys to specify the 2nd 3rd and 4th digits this applies only to 4 digit models The 1st digit is set using the UP key or DOWN key in settings where there is no decimal point this applies only to 4...

Страница 6: ... IN2 are completely independent so there is no restriction on signal timing IN1 is the counting input and IN2 is the addition or subtraction directive input IN2 adds at L level and subtracts at H level IN1 is addition input and IN2 is subtrac tion input Addition when the IN1 phase advances beyond IN2 and subtraction when the IN2 phase advances beyond IN1 0 1 2 3 n 3 n 2 n 1 n n n 1 n 2 n 3 3 2 1 0...

Страница 7: ...ultaneous with completion of count up While output is being main tained restarting of the count is not possible n Set value One shot Recount II SHOT C Output control is maintained after count up completion for one shot output time Counting is possible despite com pletion of count up However reset occurs simultaneous with output OFF n Set value One shot Hold count SHOT D Output control is maintaine...

Страница 8: ... Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 VDC max Lock input specifications Impedance during short circuit 1 kΩ max At 0 Ω the outflow current is approximately 1 5 mA Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 DVC max The contact relay should be one which can open close 5 V 1...

Страница 9: ...the count value use contacts with as short a bounce time as possible In general select Input 1 and Input 2 to have a maximum counting speed of 30 Hz and to be reset with a minimum input signal width of 20 ms 2 Non contact point input Connect with an open collector Use transistors whose characteristics satisfy the criteria given below VCEO 20 V min IC 20 mA min ICBO 6µA max Also use transistors wit...

Страница 10: ... polar full wave voltage Operating voltage Surge voltage peak value AC type 6 000V DC type 24V AC type Power supply terminals Input terminals AC type DC type 24V AC type Noise voltage 1 500V 1 000V 600V 1 000V Peak value 0 0 1 2 50 30 50 90 100 Time µs Surge voltage C C C R Fig A Fig B Operation power supply Leakage current R C Operation power supply R R C C R R Relay Counter Receive output from c...

Страница 11: ...ing use dou ble insulated relays etc 2 Always connect loads insulated with basic insulation specifications to the out put contact points The counter unit is also insulated with basic insulation speci fications The combination of the two sat isfies VDE which calls for double insula tion 3 For the applied power supply use one protected by an over current protec tion device that conforms with EN IEC ...

Отзывы: