Setting the operation mode and counter

Setting procedure 1)  Setting the operation mode (input mode and output mode)

Set the input and output modes with the DIP switches on the side of the counter.

DIP switches

Setting procedure 2)  Setting the set value

Set the set value with the UP and DOWN keys on the front of the counter.

Front display section

DIP switch

Item

DIP switch No.

1

2

3

ON

ON

ON

SHOT-A

OFF

OFF

OFF

SHOT-B

ON

OFF

OFF

SHOT-C

OFF

ON

OFF

SHOT-D

ON

ON

OFF

HOLD-A

OFF

OFF

ON

HOLD-B

ON

OFF

ON

HOLD-C

OFF

ON

ON

Output mode

Output mode

Refer to table 1

1

2

3

Minimum reset input signal width

20 ms

1 ms

4

Maximum counter setting

30 Hz

5 kHz

5

Input mode

Refer to table 2

6

7

8

ON

OFF

DIP switch No.

6

7

8

ON

ON

ON

Addition input

OFF

OFF

OFF

Subtraction input

ON

OFF

OFF

Directive input

OFF

ON

OFF

Independent input

ON

ON

OFF

Phase input

OFF

OFF

ON

ON

OFF

ON

OFF

ON

ON

(See note 1)

(See note 1)

(See note 1)

(See note 1)

Input mode

Notes:1) The counter and set value displays will display DIP Err.

Notes:

2) Set the DIP switches before installing the counter on the panel.

Notes:

3) When the DIP SW setting is changed, turn off the power once.

Notes:

4) The DIP switches are set as ON before shipping.

ON

1

5

2

3

4

6

7

8

DIP switches (See note 2)

(Same for 6-digit, screw-down terminal type)

• 4-digit display type

Q

Counter display

W

Set value display

E

Controlled output indicator

R

Reset indicator

T

Lock indicator

Y

UP keys
Changes the corresponding
digit of the set value in the
addition direction (upwards)

U

DOWN keys
Changes the corresponding digit of the set
value in the subtraction direction (down-
wards)

I

RESET switch
Resets the counting value and the output

O

SET/LOCK switch
This is used to handle pre-scaling values,
one-shot times, decimal point position set-
tings, and key lock operations (to disable Up
key, Down key, and Reset key operations).

9

8

5

4

7

6

2

1

3

DOWN

UP

SET/LOCK

RESET

LOCK

RST

OP.

LC4H

COUNTER

RESET

LOCK

RST

OP.

LC4H

COUNTER

8

7

5

4

6

2

1

3

SET/LOCK

• 6-digit display type

Q

Counter display

W

Set value display

E

Controlled output indicator

R

Reset indicator

T

Lock indicator

Y

UP keys
Changes the corresponding digit of the set
value in the addition direction (upwards)

U

RESET switch
Resets the counting value and the output

I

SET/LOCK switch
This is used to handle pre-scaling values,
one-shot times, decimal point position set-
tings, and key lock operations (to disable Up
key, Down key, and Reset key operations).

Table 1: Setting the output mode

Table 2: Setting the input mode

LC4H-S

Setting procedure 3) Setting the input mode

The input mode is set using the key switch in the [Display] section on the front of the counter.

• Decimal point position setting mode

Q

Holding down the [SET/LOCK] key, press the key for the second digit to access the decimal point position setting mode.

W

When the setting mode has been accessed, release the [SET/LOCK] key.

Example) 6-digit type
Decimal point position setting mode display
(Example shows default value displayed)

02/2003

Содержание LC4H-S

Страница 1: ...tems 6 digit display Pin type Screw terminal type PRODUCT TYPES LC4H SV A rubber gasket ATC18002 and a mounting frame AT8 DA4 are included mm inch Digit Count speed Output Operation voltage Power down Additional function Terminal P N insurane Scale Factor 11 Pin LC4H PS R4 AC240V 100 240 V AC Scale Factor Screw LC4H PS R4 AC240VS with 12V DC power supply Scale Factor Voltage Signal Input 11 Pin LC...

Страница 2: ...en collector 1 0 107 ope At rated control voltage 12 to 24 V DC 24 V AC Max 3 W 100 mA 30 V DC Transistor output type DC AC type Rating Contact Life Electrical Mechanical Operating conditions Rated operating voltage Rated frequency Rated power consumption Rated control capacity Input mode Max counting speed Counting input input 1 input 2 Reset input Lock input Input signal Output mode One shot out...

Страница 3: ...ts are attached in a continuous series the dimension of A is Device installation rail ATA48011 sold separately Min 80 3 150 Min 80 3 150 95 5 112 9 3 760 4 445 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 A 48 n 2 5 0 6 0 With power supply for sensor NO NC 3 5 4 2 1 11 10 9 8 7 6 3 5 4 2 1 11 10 9 8 7 6 NO NC 3 5 4 2 1 11 10 9 8 7 6 0 V DC 12V 100mA Max 3 5 4 2 1 11 10 9 8 7 6 0 ...

Страница 4: ...tor T Lock indicator Y UP keys Changes the corresponding digit of the set value in the addition direction upwards U DOWN keys Changes the corresponding digit of the set value in the subtraction direction down wards I RESET switch Resets the counting value and the output O SET LOCK switch This is used to handle pre scaling values one shot times decimal point position set tings and key lock operatio...

Страница 5: ...dent and phase inputs The counting value is counted up or down to any number other than 0 once When it comes to 0 zero again the counter starts counting up E The decimal point is set using the UP and DOWN keys to specify the 2nd 3rd and 4th digits this applies only to 4 digit models The 1st digit is set using the UP key or DOWN key in settings where there is no decimal point this applies only to 4...

Страница 6: ... IN2 are completely independent so there is no restriction on signal timing IN1 is the counting input and IN2 is the addition or subtraction directive input IN2 adds at L level and subtracts at H level IN1 is addition input and IN2 is subtrac tion input Addition when the IN1 phase advances beyond IN2 and subtraction when the IN2 phase advances beyond IN1 0 1 2 3 n 3 n 2 n 1 n n n 1 n 2 n 3 3 2 1 0...

Страница 7: ...ultaneous with completion of count up While output is being main tained restarting of the count is not possible n Set value One shot Recount II SHOT C Output control is maintained after count up completion for one shot output time Counting is possible despite com pletion of count up However reset occurs simultaneous with output OFF n Set value One shot Hold count SHOT D Output control is maintaine...

Страница 8: ... Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 VDC max Lock input specifications Impedance during short circuit 1 kΩ max At 0 Ω the outflow current is approximately 1 5 mA Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 DVC max The contact relay should be one which can open close 5 V 1...

Страница 9: ...the count value use contacts with as short a bounce time as possible In general select Input 1 and Input 2 to have a maximum counting speed of 30 Hz and to be reset with a minimum input signal width of 20 ms 2 Non contact point input Connect with an open collector Use transistors whose characteristics satisfy the criteria given below VCEO 20 V min IC 20 mA min ICBO 6µA max Also use transistors wit...

Страница 10: ... polar full wave voltage Operating voltage Surge voltage peak value AC type 6 000V DC type 24V AC type Power supply terminals Input terminals AC type DC type 24V AC type Noise voltage 1 500V 1 000V 600V 1 000V Peak value 0 0 1 2 50 30 50 90 100 Time µs Surge voltage C C C R Fig A Fig B Operation power supply Leakage current R C Operation power supply R R C C R R Relay Counter Receive output from c...

Страница 11: ...ing use dou ble insulated relays etc 2 Always connect loads insulated with basic insulation specifications to the out put contact points The counter unit is also insulated with basic insulation speci fications The combination of the two sat isfies VDE which calls for double insula tion 3 For the applied power supply use one protected by an over current protec tion device that conforms with EN IEC ...

Отзывы: