LC4H-S

Input connections

What is the prescale function?

The prescale function converts the count into an actual
value (amount) and displays it.

Example 
For a device that outputs 500 pulses when 1 m has been fed:

1. Set decimal position to the last 3rd place.
2. Set the prescale value to 0.002 (1/500).

• Signal input type

•) Open collector

•) For voltage output

0V

0V

Lock
input

Input

2

Input

1

Reset

input

12 V DC
output

0V

Lock
input

Input

2

Input

1

Reset

input

12 V DC
output

Output

(PC, sensor etc.)

Output

(Photoelectric sensor, 
proximity sensor, etc.)

11-pin type

Screw-down 
terminal type

11-pin type

Screw-down 
terminal type

12 V DC

0V

+

6

3

7

4

8

5

9

6

10

7

11

1

7

6

8

9

4

3

5

6

11

10

7

1

12 V DC

+

0V

Lock
input

Input

2

Input

1

Reset

input

Relay, switches etc.

11-pin type

Screw-down 
terminal type

6

3

9

8

7

10

6

5

4

7

0V

Input

2

Input

1

12 V DC
output

11-pin type

Screw-down 
terminal type

0V


phase


phase

12 V DC 

8

9

5

6

11

1

6

3

Input 1, input 2, and reset input specifications

• Impedance during short-circuit: 1 k

max.

(At 0 

, the outflow current is approximately 12 mA.)

• Residual voltage during short-circuit: 2 V max.
• Impedance when released: 100 k

min.

• Max. applied voltage: 40 VDC max.

Lock input specifications

• Impedance during short-circuit: 1 k

max.

(At 0 

, the outflow current is approximately 1.5 mA.)

• Residual voltage during short-circuit: 2 V max.
• Impedance when released: 100 k

min.

• Max. applied voltage: 40 DVC max.
• The contact relay should be one which can open/close 5 V,

1.5 mA.

* There is no 12 V DC with 12 - 24 V DC/24 V AC types.

Dual-line sensor specifications

• Leakage current: 1.5 mA max.

• Breaker capacitance: 5 mA min.

• Residual voltage: 2.0 V max.

• Usable voltage: Runs on 10 VDC

* If a dual-line sensor is connected to a 12 - 24 VDC/24 VAC type,

24 VDC (21.6 to 26.4 VDC) and 24 VAC (21.6 to 26.4 VAC)
should be applied to the power supply voltage of the counter.

6

3

8

5

9

6

10

7

0V

) For a dual-line sensor

0V

Input

2

Input

1

Reset

input

11-pin type

Screw-down 
terminal type

+

C O U N T E R

L C 4 H

UP

DOWN

RESET

SET/LOCK

C O U N T E R

L C 4 H

UP

DOWN

RESET

SET/LOCK

1m

3.281ft

Encoder

1 pulse

500 pulses

Prescale value: 0.002

Can be set to 
easy-to-understand 
unit.

•) PNP transistor type

•) Contact input

•) For a rotary encoder

sensor and others

DC12V

OUTPUT

0V

3   5 6   7  1

6     8      9    10   11

11 Pin type

Screw terminal type

0 V

Input 2

Input 1

Reset input

DC12V output

02/2003

Содержание LC4H-S

Страница 1: ...tems 6 digit display Pin type Screw terminal type PRODUCT TYPES LC4H SV A rubber gasket ATC18002 and a mounting frame AT8 DA4 are included mm inch Digit Count speed Output Operation voltage Power down Additional function Terminal P N insurane Scale Factor 11 Pin LC4H PS R4 AC240V 100 240 V AC Scale Factor Screw LC4H PS R4 AC240VS with 12V DC power supply Scale Factor Voltage Signal Input 11 Pin LC...

Страница 2: ...en collector 1 0 107 ope At rated control voltage 12 to 24 V DC 24 V AC Max 3 W 100 mA 30 V DC Transistor output type DC AC type Rating Contact Life Electrical Mechanical Operating conditions Rated operating voltage Rated frequency Rated power consumption Rated control capacity Input mode Max counting speed Counting input input 1 input 2 Reset input Lock input Input signal Output mode One shot out...

Страница 3: ...ts are attached in a continuous series the dimension of A is Device installation rail ATA48011 sold separately Min 80 3 150 Min 80 3 150 95 5 112 9 3 760 4 445 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 45 0 6 0 1 772 024 0 A 48 n 2 5 0 6 0 With power supply for sensor NO NC 3 5 4 2 1 11 10 9 8 7 6 3 5 4 2 1 11 10 9 8 7 6 NO NC 3 5 4 2 1 11 10 9 8 7 6 0 V DC 12V 100mA Max 3 5 4 2 1 11 10 9 8 7 6 0 ...

Страница 4: ...tor T Lock indicator Y UP keys Changes the corresponding digit of the set value in the addition direction upwards U DOWN keys Changes the corresponding digit of the set value in the subtraction direction down wards I RESET switch Resets the counting value and the output O SET LOCK switch This is used to handle pre scaling values one shot times decimal point position set tings and key lock operatio...

Страница 5: ...dent and phase inputs The counting value is counted up or down to any number other than 0 once When it comes to 0 zero again the counter starts counting up E The decimal point is set using the UP and DOWN keys to specify the 2nd 3rd and 4th digits this applies only to 4 digit models The 1st digit is set using the UP key or DOWN key in settings where there is no decimal point this applies only to 4...

Страница 6: ... IN2 are completely independent so there is no restriction on signal timing IN1 is the counting input and IN2 is the addition or subtraction directive input IN2 adds at L level and subtracts at H level IN1 is addition input and IN2 is subtrac tion input Addition when the IN1 phase advances beyond IN2 and subtraction when the IN2 phase advances beyond IN1 0 1 2 3 n 3 n 2 n 1 n n n 1 n 2 n 3 3 2 1 0...

Страница 7: ...ultaneous with completion of count up While output is being main tained restarting of the count is not possible n Set value One shot Recount II SHOT C Output control is maintained after count up completion for one shot output time Counting is possible despite com pletion of count up However reset occurs simultaneous with output OFF n Set value One shot Hold count SHOT D Output control is maintaine...

Страница 8: ... Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 VDC max Lock input specifications Impedance during short circuit 1 kΩ max At 0 Ω the outflow current is approximately 1 5 mA Residual voltage during short circuit 2 V max Impedance when released 100 kΩ min Max applied voltage 40 DVC max The contact relay should be one which can open close 5 V 1...

Страница 9: ...the count value use contacts with as short a bounce time as possible In general select Input 1 and Input 2 to have a maximum counting speed of 30 Hz and to be reset with a minimum input signal width of 20 ms 2 Non contact point input Connect with an open collector Use transistors whose characteristics satisfy the criteria given below VCEO 20 V min IC 20 mA min ICBO 6µA max Also use transistors wit...

Страница 10: ... polar full wave voltage Operating voltage Surge voltage peak value AC type 6 000V DC type 24V AC type Power supply terminals Input terminals AC type DC type 24V AC type Noise voltage 1 500V 1 000V 600V 1 000V Peak value 0 0 1 2 50 30 50 90 100 Time µs Surge voltage C C C R Fig A Fig B Operation power supply Leakage current R C Operation power supply R R C C R R Relay Counter Receive output from c...

Страница 11: ...ing use dou ble insulated relays etc 2 Always connect loads insulated with basic insulation specifications to the out put contact points The counter unit is also insulated with basic insulation speci fications The combination of the two sat isfies VDE which calls for double insula tion 3 For the applied power supply use one protected by an over current protec tion device that conforms with EN IEC ...

Отзывы: