84
Dimensions
(units: mm
inch
)
• Screw terminal type
• Dimensions for embedded installation (with adapter installed)
C O U N T E R
L C 4 H
UP
DOWN
RESET
SET/LOCK
s
O P.
5.5
.217
64.5
2.539
81.9*
3.224*
7.5
.295
5.5
.217
* With power supply for sensor
* With power supply for sensor
73*
2.874*
87.5*
2.445*
70.1
2.760
14.5
.571
55.6
2.189
(
48
(
1.890
(
(
44.5)
(
(
1.752)
(
(
44.5)
(
(
1.752)
(
48
(
1.890
COUNTER
LC4H
RESET
UP
DOWN
OP.
RST
LOCK
LC4H
COUNTER
RESET
1
OP.
RST
LOCK
SET/LOCK
SET/LOCK
Installation frame for
embedded installations
ATA4811 (supplied)
Installation frame for
embedded installations
ATA4811 (supplied)
Installation panel
Rubber gasket
ATC18002 (supplied)
Installation panel
Rubber gasket
ATC18002 (supplied)
11 pins cap:
ATA4861 (sold separately)
11 pin type
48
1.890
80.9
3.185
1
.039
63.5
2.500
48
1.890
90
3.543
104.5
4.114
48
1.890
48
1.890
50
1.969
50
1.969
66
2.598
66
2.598
(
44.5
(
1.752
* With power supply for sensor
* With power supply for sensor
Pin type
Pin type
Screw terminal type
Screw-down terminal type
Terminal layouts and Wiring diagrams
• Pin type
Relay output type
Transistor output type
Relay output type
* With power supply for sensor
* With power supply for sensor
Transistor output type
Relay output type
Transistor output type
Relay output type
Transistor output type
A
DIN rail terminal block
11-pin type: AT8-DF11K
(sold separately)
When n units are attached in a continuous series,
the dimension of (A) is:
Device installation rail
ATA48011
(sold separately)
Min. 80
3.150
Min. 80
3.150
95.5 (112.9)
3.760 (4.445)
45
-0.6
0
1.772
-.024
0
45
-0.6
0
1.772
-.024 0
45
-0.6
0
1.772
-.024 0
A = (48
×
n – 2.5)
–0.6
0
* With power supply for sensor
NO
NC
3
5
4
2
1 11
10
9
8
7
6
3
5
4
2
1 11
10
9
8
7
6
NO
NC
3
5
4
2
1 11
10
9
8
7
6
0 V
DC 12V
100mA Max.
3
5
4
2
1 11
10
9
8
7
6
0 V
DC 12V
100mA Max.
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
–
~
+
~
–
~
+
~
~
~
~
~
5
4
3
2
1
10
9
8
7
6
NO
NC
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
NO
NC
11
0 V
DC 12V
100mA Max.
5
4
3
2
1
10
9
8
7
6
11
0 V
DC 12V
100mA Max.
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
Operating
voltage
Reset
Lock
Input 2
Input 1
–
~
+
~
–
~
+
~
~
~
~
~
LC4H-S
Note) For connecting the output leads of the transistor output type, refer to 5) Transistor output on page 99.
(* 6-digit display type has the same dimensions.)
• Dimensions for front panel installations
• Installation panel cut-out dimensions
The standard panel cut-out dimensions are shown
below. Use the installation frame (ATA4811) and
rubber gasket (ATC18002).
• For connected installations
Note 1: The installation panel thickness should be between 1
and 5 mm
.039 and .197 inch
.
Note 2: For connected installations, the waterproofing ability
between the unit and installation panel is lost.
02/2003